2010European Journal of Mass SpectrometryRequires access

Development of Multi-Turn Time-of-Flight Mass Spectrometers and Their Applications

Michisato Toyoda

Open publisher page 29 citations

Abstract

The mass resolution of a time-of-flight (ToF) mass spectrometer is directly proportional to its total flight path length. We have developed multi-turn ToF mass spectrometers, where ions are stored in a fixed orbit within electrostatic sectors and allowed to propagate the said orbit numerous times. With each successive orbit, the flight path is correspondingly increasing. The first multi-turn ToF mass spectrometer, the MULTUM Linear plus, was developed for cometary exploration. The spectrometer consists of four cylindrical electrostatic sectors and 28 electrostatic quadrupole lenses. The size of the analyzer is 40 cm square. Mass resolution is demonstrated to increase according to the number of ion cycles. A mass resolution of greater than 350,000 was achieved after 501.5 cycles. Another multi-turn ToF mass spectrometer, the MULTUM II, which consists of only four toroidal electrostatic sectors, was also developed in an effort to reduce the number of quadrupole lenses. We are developing various types of mass spectrometer based on the MULTUM II technology, a ToF/ToF mass spectrometer "MULTUM- TOF/TOF", a stigmatic imaging mass spectrometer "MULTUM-IMG" and miniature mass spectrometers of high mass resolving power, the "MULTUM-S" series.

About this research paper

What this paper is about

The mass resolution of a time-of-flight (ToF) mass spectrometer is directly proportional to its total flight path length. We have developed multi-turn ToF mass spectrometers, where ions are stored in a fixed orbit within electrostatic sectors and allowed to propagate the said orbit numerous times. With each successive orbit, the flight path is correspondingly increasing. The first multi-turn ToF mass spectrometer, the MULTUM Linear plus, was developed for cometary exploration. The spectrometer consists of four cylindrical electrostatic sectors and 28 electrostatic quadrupole lenses. The size of the analyzer is 40 cm square. Mass resolution is demonstrated to increase according to the number of ion cycles. A mass resolution of greater than 350,000 was achieved after 501.5 cycles. Another multi-turn ToF mass spectrometer, the MULTUM II, which consists of only four toroidal electrostatic sectors, was also developed in an effort to reduce the number of quadrupole lenses. We are developing various types of mass spectrometer based on the MULTUM II technology, a ToF/ToF mass spectrometer "MULTUM- TOF/TOF", a stigmatic imaging mass spectrometer "MULTUM-IMG" and miniature mass spectrometers of high mass resolving power, the "MULTUM-S" series.

Why it matters

OpenAlex reports 29 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The mass resolution of a time-of-flight (ToF) mass spectrometer is directly proportional to its total flight path length. We have developed multi-turn ToF mass spectrometers, where ions are stored in a fixed orbit within electrostatic sectors and allowed to propagate the said orbit numerous times. With each successive orbit, the flight path is correspondingly increasing. The first multi-turn ToF mass spectrometer, the MULTUM Linear plus, was developed for cometary exploration. The spectrometer consists of four cylindrical electrostatic sectors and 28 electrostatic quadrupole lenses. The size of the analyzer is 40 cm square. Mass resolution is demonstrated to increase according to the number of ion cycles. A mass resolution of greater than 350,000 was achieved after 501.5 cycles. Another multi-turn ToF mass spectrometer, the MULTUM II, which consists of only four toroidal electrostatic sectors, was also developed in an effort to reduce the number of quadrupole lenses. We are developing various types of mass spectrometer based on the MULTUM II technology, a ToF/ToF mass spectrometer "MULTUM- TOF/TOF", a stigmatic imaging mass spectrometer "MULTUM-IMG" and miniature mass spectrometers of high mass resolving power, the "MULTUM-S" series.

Key concepts: Mass spectrometry, Quadrupole mass analyzer, Hybrid mass spectrometer, Spectrometer, Time of flight, Secondary ion mass spectrometry, Time-of-flight mass spectrometry, Resolution (logic)

Related papers

Back to paper searchBrowse research topicsOriginal source
Development of Multi-Turn Time-of-Flight Mass Spectrometers and Their Applications — Research Paper | ScholarLens