2008Chemical Engineering CommunicationsRequires access

INFLUENCE OF THE DISTRIBUTOR PLATE AND OPERATING CONDITIONS ON THE FLUIDIZATION QUALITY OF A GAS FLUIDIZED BED

João Monney Paiva, Carlos Pinho, A.R. Figueiredo

Open publisher page 9 citations

Abstract

Experiments were carried out to examine the influence of both the type and the pressure drop of distributor plates on the fluidization quality of an atmospheric fluidized bed. Three different distributor types were used, perforated Perspex, metallic mesh, and porous ceramic, with pressure drops ranging from 0.05 to 350 kPa and superficial air velocities ranging from 0.1 to 2.3 m/s. Three sizes of silica Ballotini beads, 355–425, 600–710, and 850–1000 µm, were used as bed material. The static bed height was set to 300 mm and was divided into six horizontal 50 mm high slices. For each slice, pressure drop values were recorded for U0/Umf ratios from 20 to 1. In order to produce a reference for the pressure drop evolution, a modification of the two-phase theory was introduced, taking into consideration the increase in the average global porosity as well as the change in the ratio of flow through the bubbles versus the flow through the dense phase. This allowed assessment of the influence of the different operating conditions and setups on the quality of fluidization, Q∗.

About this research paper

What this paper is about

Experiments were carried out to examine the influence of both the type and the pressure drop of distributor plates on the fluidization quality of an atmospheric fluidized bed. Three different distributor types were used, perforated Perspex, metallic mesh, and porous ceramic, with pressure drops ranging from 0.05 to 350 kPa and superficial air velocities ranging from 0.1 to 2.3 m/s. Three sizes of silica Ballotini beads, 355–425, 600–710, and 850–1000 µm, were used as bed material. The static bed height was set to 300 mm and was divided into six horizontal 50 mm high slices. For each slice, pressure drop values were recorded for U0/Umf ratios from 20 to 1. In order to produce a reference for the pressure drop evolution, a modification of the two-phase theory was introduced, taking into consideration the increase in the average global porosity as well as the change in the ratio of flow through the bubbles versus the flow through the dense phase. This allowed assessment of the influence of the different operating conditions and setups on the quality of fluidization, Q∗.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Experiments were carried out to examine the influence of both the type and the pressure drop of distributor plates on the fluidization quality of an atmospheric fluidized bed. Three different distributor types were used, perforated Perspex, metallic mesh, and porous ceramic, with pressure drops ranging from 0.05 to 350 kPa and superficial air velocities ranging from 0.1 to 2.3 m/s. Three sizes of silica Ballotini beads, 355–425, 600–710, and 850–1000 µm, were used as bed material. The static bed height was set to 300 mm and was divided into six horizontal 50 mm high slices. For each slice, pressure drop values were recorded for U0/Umf ratios from 20 to 1. In order to produce a reference for the pressure drop evolution, a modification of the two-phase theory was introduced, taking into consideration the increase in the average global porosity as well as the change in the ratio of flow through the bubbles versus the flow through the dense phase. This allowed assessment of the influence of the different operating conditions and setups on the quality of fluidization, Q∗.

Key concepts: Fluidization, Distributor, Pressure drop, Fluidized bed, Porosity, Materials science, Ceramic, Mechanics

Related papers

Back to paper searchBrowse research topicsOriginal source
INFLUENCE OF THE DISTRIBUTOR PLATE AND OPERATING CONDITIONS ON THE FLUIDIZATION QUALITY OF A GAS FLUIDIZED BED — Research Paper | ScholarLens