1993The AnalystRequires access

L -Cysteine as a reducing and releasing agent for the determination of antimony and arsenic using flow injection hydride generation atomic absorption spectrometry—Part 1. Optimization of the analytical parameters

Bernhard Welz, Marcella Šucmanová

Open publisher page 82 citations

Abstract

L-Cysteine was investigated as the reducing and releasing agent for the determination of antimony and arsenic using flow injection hydride generation atomic absorption spectrometry with the aim of replacing the previously used potassium iodide. The prereduction of the pentavalent to the trivalent form at room temperature was completed within 5 and 30 min for antimony and arsenic, respectively, which was essentially identical with the performance of potassium iodide. However, much lower acid and reagent concentrations were required with L-cysteine than with potassium iodide. In addition, even dilute analyte solutions containing L-cysteine were stable for at least one week, whereas solutions containing potassium iodide had to be prepared fresh daily. Under optimized conditions, in the presence of 1% m/v L-cysteine and 1 mol l–1 HCI for antimony or 0.1 mol l–1 HCI for arsenic, detection limits (three times the standard deviation of a blank solution, n= 10) of 0.05 and 0.01 µg l–1 were obtained for antimony and arsenic. The calibration graphs were linear (r > 0.999) for up to 10 µg l–1 of antimony and 5 µg l–1 of arsenic, using integrated absorbance for evaluation. The precision was better than 2% relative standard deviation (n= 10) for both elements at the 5 µg l–1 concentration level.

About this research paper

What this paper is about

L-Cysteine was investigated as the reducing and releasing agent for the determination of antimony and arsenic using flow injection hydride generation atomic absorption spectrometry with the aim of replacing the previously used potassium iodide. The prereduction of the pentavalent to the trivalent form at room temperature was completed within 5 and 30 min for antimony and arsenic, respectively, which was essentially identical with the performance of potassium iodide. However, much lower acid and reagent concentrations were required with L-cysteine than with potassium iodide. In addition, even dilute analyte solutions containing L-cysteine were stable for at least one week, whereas solutions containing potassium iodide had to be prepared fresh daily. Under optimized conditions, in the presence of 1% m/v L-cysteine and 1 mol l–1 HCI for antimony or 0.1 mol l–1 HCI for arsenic, detection limits (three times the standard deviation of a blank solution, n= 10) of 0.05 and 0.01 µg l–1 were obtained for antimony and arsenic. The calibration graphs were linear (r > 0.999) for up to 10 µg l–1 of antimony and 5 µg l–1 of arsenic, using integrated absorbance for evaluation. The precision was better than 2% relative standard deviation (n= 10) for both elements at the 5 µg l–1 concentration level.

Why it matters

OpenAlex reports 82 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

L-Cysteine was investigated as the reducing and releasing agent for the determination of antimony and arsenic using flow injection hydride generation atomic absorption spectrometry with the aim of replacing the previously used potassium iodide. The prereduction of the pentavalent to the trivalent form at room temperature was completed within 5 and 30 min for antimony and arsenic, respectively, which was essentially identical with the performance of potassium iodide. However, much lower acid and reagent concentrations were required with L-cysteine than with potassium iodide. In addition, even dilute analyte solutions containing L-cysteine were stable for at least one week, whereas solutions containing potassium iodide had to be prepared fresh daily. Under optimized conditions, in the presence of 1% m/v L-cysteine and 1 mol l–1 HCI for antimony or 0.1 mol l–1 HCI for arsenic, detection limits (three times the standard deviation of a blank solution, n= 10) of 0.05 and 0.01 µg l–1 were obtained for antimony and arsenic. The calibration graphs were linear (r > 0.999) for up to 10 µg l–1 of antimony and 5 µg l–1 of arsenic, using integrated absorbance for evaluation. The precision was better than 2% relative standard deviation (n= 10) for both elements at the 5 µg l–1 concentration level.

Key concepts: Antimony, Chemistry, Arsenic, Hydride, Detection limit, Reagent, Atomic absorption spectroscopy, Iodide

Related papers

Back to paper searchBrowse research topicsOriginal source
L -Cysteine as a reducing and releasing agent for the determination of antimony and arsenic using flow injection hydride generation atomic absorption spectrometry—Part 1. Optimization of the analytical parameters — Research Paper | ScholarLens