2012•Unpublished venueRequires access

A Biomechanical and Biochemical Synergy Study of Heart Valve Tissue

Hsiao‐Ying Shadow Huang, Brittany N. Balhouse, Siyao Huang

Open publisher page 1 citations

Abstract

The function of heart valves is to allow blood to flow through the heart smoothly and to prevent retrograde flow of blood. Previous studies have shown that the mechanical properties of heart valve tissues, microstructures of extracellular matrix, and collagen concentrations are the keys to the healthy heart valves and, therefore, are crucial to the development of viable tissue-engineered heart valve replacements. Therefore, this study investigates the relationship between these factors in native porcine aortic and pulmonary valves and provides insights to the healthy heart valves. Heart valve leaflets are prepared for biaxial stretching to obtain mechanical properties. The average collagen concentrations of heart valve leaflets are determined via an assay kit. The results indicate that aortic valves are stiffer than pulmonary valves macroscopically and stiffness varies more in the circumferential direction for the aortic valve than it does for the pulmonary valve. Microscopically, it is due to collagen fibers in aortic valves are more in alignment than ones in pulmonary valves, which are more randomly in direction. Collagen assay results show that collagen concentrations are higher in the edges of pulmonary valves than in aortic valves. The results also suggest the duration of extraction may have significant affects on the concentration results. This work provides quantified stress and strain environment within heart valve tissues to help further studies on how to treat heart valve disease and create more viable heart valve replacements.

About this research paper

What this paper is about

The function of heart valves is to allow blood to flow through the heart smoothly and to prevent retrograde flow of blood. Previous studies have shown that the mechanical properties of heart valve tissues, microstructures of extracellular matrix, and collagen concentrations are the keys to the healthy heart valves and, therefore, are crucial to the development of viable tissue-engineered heart valve replacements. Therefore, this study investigates the relationship between these factors in native porcine aortic and pulmonary valves and provides insights to the healthy heart valves. Heart valve leaflets are prepared for biaxial stretching to obtain mechanical properties. The average collagen concentrations of heart valve leaflets are determined via an assay kit. The results indicate that aortic valves are stiffer than pulmonary valves macroscopically and stiffness varies more in the circumferential direction for the aortic valve than it does for the pulmonary valve. Microscopically, it is due to collagen fibers in aortic valves are more in alignment than ones in pulmonary valves, which are more randomly in direction. Collagen assay results show that collagen concentrations are higher in the edges of pulmonary valves than in aortic valves. The results also suggest the duration of extraction may have significant affects on the concentration results. This work provides quantified stress and strain environment within heart valve tissues to help further studies on how to treat heart valve disease and create more viable heart valve replacements.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The function of heart valves is to allow blood to flow through the heart smoothly and to prevent retrograde flow of blood. Previous studies have shown that the mechanical properties of heart valve tissues, microstructures of extracellular matrix, and collagen concentrations are the keys to the healthy heart valves and, therefore, are crucial to the development of viable tissue-engineered heart valve replacements. Therefore, this study investigates the relationship between these factors in native porcine aortic and pulmonary valves and provides insights to the healthy heart valves. Heart valve leaflets are prepared for biaxial stretching to obtain mechanical properties. The average collagen concentrations of heart valve leaflets are determined via an assay kit. The results indicate that aortic valves are stiffer than pulmonary valves macroscopically and stiffness varies more in the circumferential direction for the aortic valve than it does for the pulmonary valve. Microscopically, it is due to collagen fibers in aortic valves are more in alignment than ones in pulmonary valves, which are more randomly in direction. Collagen assay results show that collagen concentrations are higher in the edges of pulmonary valves than in aortic valves. The results also suggest the duration of extraction may have significant affects on the concentration results. This work provides quantified stress and strain environment within heart valve tissues to help further studies on how to treat heart valve disease and create more viable heart valve replacements.

Key concepts: Heart valve, Aortic valve, Pulmonary valve, Cardiology, Biomedical engineering, Internal medicine, Mechanical heart-valve, Aorta

Related papers

Back to paper searchBrowse research topicsOriginal source
A Biomechanical and Biochemical Synergy Study of Heart Valve Tissue — Research Paper | ScholarLens