2000•Journal of Clinical MicrobiologyOpen access

Performance of Three Enzyme Immunoassays and Two Direct Fluorescence Assays for Detection of Giardia lamblia in Stool Specimens Preserved in ECOFIX

Daniel P. Fedorko, Esther C. Williams, Nancy A. Nelson, Leslie B. Calhoun, Sizhuang Yan

Open full text 21 citations

Abstract

ECOFIX is a single-vial stool preservative that is both formalin- and mercury-free. We evaluated the abilities of three commercial Giardia lamblia-specific enzyme immunoassays (EIAs) (ProSpecT Giardia Microplate Assay [Alexon-Trend Inc.], Giardia Test [Techlab], and Premier Giardia lamblia [Meridian Diagnostics, Inc.]) and two commercial direct fluorescent-antibody (FA) assays for G. lamblia (Crypto/Giardia IF Test [Techlab] and Merifluor Cryptosporidium/Giardia [Meridian Diagnostics, Inc.]) to detect G. lamblia in 34 G. lamblia-positive and 44 G. lamblia-negative stool specimens (determined by traditional examination for ova and parasites) preserved in ECOFIX compared to their abilities to detect G. lamblia in the same specimens preserved in formalin as the "gold standard" for each assay. Of the 34 formalin-fixed positive specimens, the number detected by each assay was as follows:, Alexon EIA, 34; Meridian EIA, 27; Techlab EIA, 29; Meridian FA assay, 31; and Techlab FA assay, 28. Both FA tests and the Alexon EIA performed well with ECOFIX, but the other two EIAs detected fewer positive specimens (the difference was statistically significant with the Techlab EIA) when ECOFIX was the preservative. Use of G. lamblia cyst antigen from cultured organisms preserved in formalin and ECOFIX demonstrated that the Alexon EIA could detect smaller amounts of antigen in ECOFIX than the other two EIAs could and suggested that cyst antigen is more stable in formalin. We recommend that laboratories use an FA assay or the Alexon EIA if they plan to use ECOFIX as their stool preservative.

About this research paper

What this paper is about

ECOFIX is a single-vial stool preservative that is both formalin- and mercury-free. We evaluated the abilities of three commercial Giardia lamblia-specific enzyme immunoassays (EIAs) (ProSpecT Giardia Microplate Assay [Alexon-Trend Inc.], Giardia Test [Techlab], and Premier Giardia lamblia [Meridian Diagnostics, Inc.]) and two commercial direct fluorescent-antibody (FA) assays for G. lamblia (Crypto/Giardia IF Test [Techlab] and Merifluor Cryptosporidium/Giardia [Meridian Diagnostics, Inc.]) to detect G. lamblia in 34 G. lamblia-positive and 44 G. lamblia-negative stool specimens (determined by traditional examination for ova and parasites) preserved in ECOFIX compared to their abilities to detect G. lamblia in the same specimens preserved in formalin as the "gold standard" for each assay. Of the 34 formalin-fixed positive specimens, the number detected by each assay was as follows:, Alexon EIA, 34; Meridian EIA, 27; Techlab EIA, 29; Meridian FA assay, 31; and Techlab FA assay, 28. Both FA tests and the Alexon EIA performed well with ECOFIX, but the other two EIAs detected fewer positive specimens (the difference was statistically significant with the Techlab EIA) when ECOFIX was the preservative. Use of G. lamblia cyst antigen from cultured organisms preserved in formalin and ECOFIX demonstrated that the Alexon EIA could detect smaller amounts of antigen in ECOFIX than the other two EIAs could and suggested that cyst antigen is more stable in formalin. We recommend that laboratories use an FA assay or the Alexon EIA if they plan to use ECOFIX as their stool preservative.

Why it matters

OpenAlex reports 21 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

ECOFIX is a single-vial stool preservative that is both formalin- and mercury-free. We evaluated the abilities of three commercial Giardia lamblia-specific enzyme immunoassays (EIAs) (ProSpecT Giardia Microplate Assay [Alexon-Trend Inc.], Giardia Test [Techlab], and Premier Giardia lamblia [Meridian Diagnostics, Inc.]) and two commercial direct fluorescent-antibody (FA) assays for G. lamblia (Crypto/Giardia IF Test [Techlab] and Merifluor Cryptosporidium/Giardia [Meridian Diagnostics, Inc.]) to detect G. lamblia in 34 G. lamblia-positive and 44 G. lamblia-negative stool specimens (determined by traditional examination for ova and parasites) preserved in ECOFIX compared to their abilities to detect G. lamblia in the same specimens preserved in formalin as the "gold standard" for each assay. Of the 34 formalin-fixed positive specimens, the number detected by each assay was as follows:, Alexon EIA, 34; Meridian EIA, 27; Techlab EIA, 29; Meridian FA assay, 31; and Techlab FA assay, 28. Both FA tests and the Alexon EIA performed well with ECOFIX, but the other two EIAs detected fewer positive specimens (the difference was statistically significant with the Techlab EIA) when ECOFIX was the preservative. Use of G. lamblia cyst antigen from cultured organisms preserved in formalin and ECOFIX demonstrated that the Alexon EIA could detect smaller amounts of antigen in ECOFIX than the other two EIAs could and suggested that cyst antigen is more stable in formalin. We recommend that laboratories use an FA assay or the Alexon EIA if they plan to use ECOFIX as their stool preservative.

Key concepts: Giardia lamblia, Giardia, Cryptosporidium, Biology, Microbiology, Antigen, Immunoassay, Antibody

Related papers

Back to paper searchBrowse research topicsOriginal source
Performance of Three Enzyme Immunoassays and Two Direct Fluorescence Assays for Detection of Giardia lamblia in Stool Specimens Preserved in ECOFIX — Research Paper | ScholarLens