2014Journal of Oral ImplantologyOpen access

Effect of Luting Agents on Retention of Dental Implant-Supported Prostheses

Yu‐Hwa Pan, Tai-Min Lin, Perng‐Ru Liu, Lance C. Ramp

Open full text 5 citations

Abstract

To evaluate the retentive strength of 7 different luting agents in cement-retained implant abutment/analog assemblies. Fifty-six externally hexed dental implant abutment/analog assemblies and cast superstructures were divided randomly into 7 groups for cementation with each of the 7 luting agents. Five definitive cements tested were zinc phosphate cement, All-Bond 2, Maxcem, RelyX Luting cement, HY-Bond, and two provisional cements, ImProv and Premier. Cast superstructures were cemented onto the implant abutments and exposed to 1000 thermal cycles (0°C-55°C) and 100 000 cycles on a chewing simulator (75 N load). A universal testing machine was used to measure cement failure load of the assembled specimens. Cement failure load was evaluated with 1-way ANOVA and Duncan's multiple range analysis. Significant differences in cement failure loads were measured (P < .0001). Post hoc testing with Duncan's multiple range indicated 4 separate groupings. Maxcem and All-Bond 2 were comparable, having the greatest load failure. RelyX and zinc phosphate cement were analogous, and higher than HY-Bond. Improv and Premier constituted a pair, which demonstrated the lowest retentive values. Within the limitations of this in vitro study, Maxcem and All-Bond 2 are good candidates for cement-retained implant prostheses while concerning retention.

Open-access reader

About this research paper

What this paper is about

To evaluate the retentive strength of 7 different luting agents in cement-retained implant abutment/analog assemblies. Fifty-six externally hexed dental implant abutment/analog assemblies and cast superstructures were divided randomly into 7 groups for cementation with each of the 7 luting agents. Five definitive cements tested were zinc phosphate cement, All-Bond 2, Maxcem, RelyX Luting cement, HY-Bond, and two provisional cements, ImProv and Premier. Cast superstructures were cemented onto the implant abutments and exposed to 1000 thermal cycles (0°C-55°C) and 100 000 cycles on a chewing simulator (75 N load). A universal testing machine was used to measure cement failure load of the assembled specimens. Cement failure load was evaluated with 1-way ANOVA and Duncan's multiple range analysis. Significant differences in cement failure loads were measured (P < .0001). Post hoc testing with Duncan's multiple range indicated 4 separate groupings. Maxcem and All-Bond 2 were comparable, having the greatest load failure. RelyX and zinc phosphate cement were analogous, and higher than HY-Bond. Improv and Premier constituted a pair, which demonstrated the lowest retentive values. Within the limitations of this in vitro study, Maxcem and All-Bond 2 are good candidates for cement-retained implant prostheses while concerning retention.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To evaluate the retentive strength of 7 different luting agents in cement-retained implant abutment/analog assemblies. Fifty-six externally hexed dental implant abutment/analog assemblies and cast superstructures were divided randomly into 7 groups for cementation with each of the 7 luting agents. Five definitive cements tested were zinc phosphate cement, All-Bond 2, Maxcem, RelyX Luting cement, HY-Bond, and two provisional cements, ImProv and Premier. Cast superstructures were cemented onto the implant abutments and exposed to 1000 thermal cycles (0°C-55°C) and 100 000 cycles on a chewing simulator (75 N load). A universal testing machine was used to measure cement failure load of the assembled specimens. Cement failure load was evaluated with 1-way ANOVA and Duncan's multiple range analysis. Significant differences in cement failure loads were measured (P < .0001). Post hoc testing with Duncan's multiple range indicated 4 separate groupings. Maxcem and All-Bond 2 were comparable, having the greatest load failure. RelyX and zinc phosphate cement were analogous, and higher than HY-Bond. Improv and Premier constituted a pair, which demonstrated the lowest retentive values. Within the limitations of this in vitro study, Maxcem and All-Bond 2 are good candidates for cement-retained implant prostheses while concerning retention.

Key concepts: Cement, Cementation (geology), Luting agent, Implant, Bond strength, Abutment, Zinc phosphate, Dentistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of Luting Agents on Retention of Dental Implant-Supported Prostheses — Research Paper | ScholarLens