1986FEMS Microbiology LettersRequires access

Assay of IgA toShigella flexneriduring shigellosis

Ch.G. van Bohemen, A. J. J. M. Nabbe, Jan Weel, J. E. Landheer, H. C. Zanen

Open publisher page 3 citations

Abstract

An enzyme-linked immunosorbent assay (ELISA) to Shigella flexneri 2a whole bacterium was used to determine IgM, IgG and IgA serum titers in 50 acute-phase shigellosis patients and 37 controls, i.e., hospital patients without known recent infections. Compared to controls, the shigellosis patients displayed statistically raised average serum titers to S. flexneri in all 3 above immunoglobulin classes, most notably IgA, which displayed an average 42-fold increase. Specific IgM and IgG were 5- and 16-fold higher, respectively. All sera displayed statistically raised titers in at least one immunoglobulin class. A Widal agglutination detected a 7-fold increase in serum titers; this was comparable to the IgM ELISA. Statistical analysis showed that the intra-assay error of the ELISA varied from 5 to 14%, depending on the absorbance from which titers were calculated. A second ELISA was performed on the above shigellosis sera to determine titers to purified lipopolysaccharide (LPS): a statistical correlation was found between these and the above values for all 3 immunoglobulin classes. We conclude that the use of S. flexneri whole bacterium as an antigen in an IgA ELISA is a statistically valid and convenient parameter for monitoring shigellosis, comparable to the use of LPS as antigen, and more sensitive than IgM or IgG ELISAs or agglutinations.

About this research paper

What this paper is about

An enzyme-linked immunosorbent assay (ELISA) to Shigella flexneri 2a whole bacterium was used to determine IgM, IgG and IgA serum titers in 50 acute-phase shigellosis patients and 37 controls, i.e., hospital patients without known recent infections. Compared to controls, the shigellosis patients displayed statistically raised average serum titers to S. flexneri in all 3 above immunoglobulin classes, most notably IgA, which displayed an average 42-fold increase. Specific IgM and IgG were 5- and 16-fold higher, respectively. All sera displayed statistically raised titers in at least one immunoglobulin class. A Widal agglutination detected a 7-fold increase in serum titers; this was comparable to the IgM ELISA. Statistical analysis showed that the intra-assay error of the ELISA varied from 5 to 14%, depending on the absorbance from which titers were calculated. A second ELISA was performed on the above shigellosis sera to determine titers to purified lipopolysaccharide (LPS): a statistical correlation was found between these and the above values for all 3 immunoglobulin classes. We conclude that the use of S. flexneri whole bacterium as an antigen in an IgA ELISA is a statistically valid and convenient parameter for monitoring shigellosis, comparable to the use of LPS as antigen, and more sensitive than IgM or IgG ELISAs or agglutinations.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An enzyme-linked immunosorbent assay (ELISA) to Shigella flexneri 2a whole bacterium was used to determine IgM, IgG and IgA serum titers in 50 acute-phase shigellosis patients and 37 controls, i.e., hospital patients without known recent infections. Compared to controls, the shigellosis patients displayed statistically raised average serum titers to S. flexneri in all 3 above immunoglobulin classes, most notably IgA, which displayed an average 42-fold increase. Specific IgM and IgG were 5- and 16-fold higher, respectively. All sera displayed statistically raised titers in at least one immunoglobulin class. A Widal agglutination detected a 7-fold increase in serum titers; this was comparable to the IgM ELISA. Statistical analysis showed that the intra-assay error of the ELISA varied from 5 to 14%, depending on the absorbance from which titers were calculated. A second ELISA was performed on the above shigellosis sera to determine titers to purified lipopolysaccharide (LPS): a statistical correlation was found between these and the above values for all 3 immunoglobulin classes. We conclude that the use of S. flexneri whole bacterium as an antigen in an IgA ELISA is a statistically valid and convenient parameter for monitoring shigellosis, comparable to the use of LPS as antigen, and more sensitive than IgM or IgG ELISAs or agglutinations.

Key concepts: Shigellosis, Shigella flexneri, Titer, Shigella, Immunoglobulin G, Immunoglobulin M, Immunoglobulin A, Microbiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Assay of IgA toShigella flexneriduring shigellosis — Research Paper | ScholarLens