An enzyme-linked immunosorbent assay (ELISA) to Shigella flexneri 2a whole bacterium was used to determine IgM, IgG and IgA serum titers in 50 acute-phase shigellosis patients and 37 controls, i.e., hospital patients without known recent infections. Compared to controls, the shigellosis patients displayed statistically raised average serum titers to S. flexneri in all 3 above immunoglobulin classes, most notably IgA, which displayed an average 42-fold increase. Specific IgM and IgG were 5- and 16-fold higher, respectively. All sera displayed statistically raised titers in at least one immunoglobulin class. A Widal agglutination detected a 7-fold increase in serum titers; this was comparable to the IgM ELISA. Statistical analysis showed that the intra-assay error of the ELISA varied from 5 to 14%, depending on the absorbance from which titers were calculated. A second ELISA was performed on the above shigellosis sera to determine titers to purified lipopolysaccharide (LPS): a statistical correlation was found between these and the above values for all 3 immunoglobulin classes. We conclude that the use of S. flexneri whole bacterium as an antigen in an IgA ELISA is a statistically valid and convenient parameter for monitoring shigellosis, comparable to the use of LPS as antigen, and more sensitive than IgM or IgG ELISAs or agglutinations.
OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
An enzyme-linked immunosorbent assay (ELISA) to Shigella flexneri 2a whole bacterium was used to determine IgM, IgG and IgA serum titers in 50 acute-phase shigellosis patients and 37 controls, i.e., hospital patients without known recent infections. Compared to controls, the shigellosis patients displayed statistically raised average serum titers to S. flexneri in all 3 above immunoglobulin classes, most notably IgA, which displayed an average 42-fold increase. Specific IgM and IgG were 5- and 16-fold higher, respectively. All sera displayed statistically raised titers in at least one immunoglobulin class. A Widal agglutination detected a 7-fold increase in serum titers; this was comparable to the IgM ELISA. Statistical analysis showed that the intra-assay error of the ELISA varied from 5 to 14%, depending on the absorbance from which titers were calculated. A second ELISA was performed on the above shigellosis sera to determine titers to purified lipopolysaccharide (LPS): a statistical correlation was found between these and the above values for all 3 immunoglobulin classes. We conclude that the use of S. flexneri whole bacterium as an antigen in an IgA ELISA is a statistically valid and convenient parameter for monitoring shigellosis, comparable to the use of LPS as antigen, and more sensitive than IgM or IgG ELISAs or agglutinations.
Key concepts: Shigellosis, Shigella flexneri, Titer, Shigella, Immunoglobulin G, Immunoglobulin M, Immunoglobulin A, Microbiology