2009Journal of Separation ScienceRequires access

Capillary electrophoresis using core‐based hyperbranched polyethyleneimine (CHPEI) static‐coated capillaries

Cheerapa Boonyakong, Sheryl A. Tucker

Open publisher page 6 citations

Abstract

With unique 3-D architecture, the application of core-based hyperbranched polyethyleneimine (CHPEI), as a capillary coating in capillary electrophoresis, is demonstrated by manipulation of the electroosmotic mobility (EOF). CHPEI coatings (CHPEI5, M(w) approximately 5000 and CHPEI25, M(w) approximately 25,000) were physically adsorbed onto the inner surface of bare fused-silica capillary (BFS) via electrostatic interaction of the oppositely charged molecules by rinsing the capillaries with different CHPEI aqueous solutions. The EOF values of the coated capillaries were measured over the pH range of 4.0-9.0. At higher pH (pH >6) the coated capillary surface possesses excess negative charges, which causes the reversal of the EOF. The magnitudes of the EOF obtained from the coated capillaries were three-fold lower than that of BFS capillary. Desirable reproducibility of the EOF with % RSD (n = 5) < or = 2 was obtained. Effect of ionic strength, stability of the coating (% RSD = 0.3) and the dependence of the EOF on pH (% RSD = 0.5) were also investigated. The CHPEI-coated capillaries were successfully utilized to separate phenolic compounds, B vitamins, as well as basic drugs and related compounds with reasonable analysis time (< 20 min) and acceptable migration-time repeatability (< 0.7% RSD for intra-capillary and < 2% RSD for inter-capillary).

About this research paper

What this paper is about

With unique 3-D architecture, the application of core-based hyperbranched polyethyleneimine (CHPEI), as a capillary coating in capillary electrophoresis, is demonstrated by manipulation of the electroosmotic mobility (EOF). CHPEI coatings (CHPEI5, M(w) approximately 5000 and CHPEI25, M(w) approximately 25,000) were physically adsorbed onto the inner surface of bare fused-silica capillary (BFS) via electrostatic interaction of the oppositely charged molecules by rinsing the capillaries with different CHPEI aqueous solutions. The EOF values of the coated capillaries were measured over the pH range of 4.0-9.0. At higher pH (pH >6) the coated capillary surface possesses excess negative charges, which causes the reversal of the EOF. The magnitudes of the EOF obtained from the coated capillaries were three-fold lower than that of BFS capillary. Desirable reproducibility of the EOF with % RSD (n = 5) < or = 2 was obtained. Effect of ionic strength, stability of the coating (% RSD = 0.3) and the dependence of the EOF on pH (% RSD = 0.5) were also investigated. The CHPEI-coated capillaries were successfully utilized to separate phenolic compounds, B vitamins, as well as basic drugs and related compounds with reasonable analysis time (< 20 min) and acceptable migration-time repeatability (< 0.7% RSD for intra-capillary and < 2% RSD for inter-capillary).

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

With unique 3-D architecture, the application of core-based hyperbranched polyethyleneimine (CHPEI), as a capillary coating in capillary electrophoresis, is demonstrated by manipulation of the electroosmotic mobility (EOF). CHPEI coatings (CHPEI5, M(w) approximately 5000 and CHPEI25, M(w) approximately 25,000) were physically adsorbed onto the inner surface of bare fused-silica capillary (BFS) via electrostatic interaction of the oppositely charged molecules by rinsing the capillaries with different CHPEI aqueous solutions. The EOF values of the coated capillaries were measured over the pH range of 4.0-9.0. At higher pH (pH >6) the coated capillary surface possesses excess negative charges, which causes the reversal of the EOF. The magnitudes of the EOF obtained from the coated capillaries were three-fold lower than that of BFS capillary. Desirable reproducibility of the EOF with % RSD (n = 5) < or = 2 was obtained. Effect of ionic strength, stability of the coating (% RSD = 0.3) and the dependence of the EOF on pH (% RSD = 0.5) were also investigated. The CHPEI-coated capillaries were successfully utilized to separate phenolic compounds, B vitamins, as well as basic drugs and related compounds with reasonable analysis time (< 20 min) and acceptable migration-time repeatability (< 0.7% RSD for intra-capillary and < 2% RSD for inter-capillary).

Key concepts: Capillary action, Capillary electrophoresis, Repeatability, Coating, Chemistry, Capillary electrochromatography, Chromatography, Reproducibility

Related papers

Back to paper searchBrowse research topicsOriginal source
Capillary electrophoresis using core‐based hyperbranched polyethyleneimine (CHPEI) static‐coated capillaries — Research Paper | ScholarLens