2013Vascular and Endovascular SurgeryRequires access

The Upside Down Endurant Iliac Limb Stent Graft for Treatment of a Common Iliac Artery Aneurysm

Yuya Koike, Junichi Nishimura, Soichiro Hase, Motoshige Yamasaki

Open publisher page 12 citations

Abstract

Endovascular repair of the coverage from the common iliac artery to the external iliac artery after the internal iliac artery embolization has been proven to be a safe and effective treatment in isolated iliac artery aneurysms. But in cases in which the diameter of the proximal sealing zone is larger than that of the distal sealing zone, a reverse-tapered device is needed. We described the off-label use of the Endurant iliac limb stent graft in an upside down configuration to accommodate this diameter mismatch.

About this research paper

What this paper is about

Endovascular repair of the coverage from the common iliac artery to the external iliac artery after the internal iliac artery embolization has been proven to be a safe and effective treatment in isolated iliac artery aneurysms. But in cases in which the diameter of the proximal sealing zone is larger than that of the distal sealing zone, a reverse-tapered device is needed. We described the off-label use of the Endurant iliac limb stent graft in an upside down configuration to accommodate this diameter mismatch.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Endovascular repair of the coverage from the common iliac artery to the external iliac artery after the internal iliac artery embolization has been proven to be a safe and effective treatment in isolated iliac artery aneurysms. But in cases in which the diameter of the proximal sealing zone is larger than that of the distal sealing zone, a reverse-tapered device is needed. We described the off-label use of the Endurant iliac limb stent graft in an upside down configuration to accommodate this diameter mismatch.

Key concepts: Medicine, Internal iliac artery, Iliac artery, Common iliac artery, Stent, External iliac artery, Surgery, Embolization

Related papers

Back to paper searchBrowse research topicsOriginal source
The Upside Down Endurant Iliac Limb Stent Graft for Treatment of a Common Iliac Artery Aneurysm — Research Paper | ScholarLens