A Digestion Procedure for the Simultaneous Determination of Total Nitrogen and Total Phosphorus in Pond Water
Amit Gross, Claude E. Boyd
Abstract
Open-access reader
Amit Gross, Claude E. Boyd
Abstract
Open-access reader
Abstract— Total phosphorus and total nitrogen often are measured in studies of pond water quality. A laboratory study was conducted to test a digestion procedure for the simultaneous determination of total nitrogen and total phosphorus in pond water. Seventy water samples were collected from channel catfish ponds. Samples were digested in two ways. One digestion followed the standard protocol of persulfate digestion in an acidic environment for total phosphorus analysis, and total phosphorus was then measured with the ascorbic acid procedure. The second digestion was done by the procedure used for determining total nitrogen which involves persulfate digestion in an alkaline environment. The total nitrogen digestion procedure followed by phosphorus determination provided results similar to those obtained in the standard persulfate digestion for phosphorus. The slope of the regression line did not differ from 1.0 (P < 0.05) and the Y intercept did not differ from 0 (P < 0.05). Spike recovery averaged 99.1% (range 85–112%) in the total nitrogen digestion procedure; it averaged 98.4% (range 88–113%) in the standard total phosphorus digestion. The results of this investigation indicated that a single digestion can be used to obtain a digest suitable for measurements of total nitrogen and total phosphorus.
OpenAlex reports 111 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Abstract— Total phosphorus and total nitrogen often are measured in studies of pond water quality. A laboratory study was conducted to test a digestion procedure for the simultaneous determination of total nitrogen and total phosphorus in pond water. Seventy water samples were collected from channel catfish ponds. Samples were digested in two ways. One digestion followed the standard protocol of persulfate digestion in an acidic environment for total phosphorus analysis, and total phosphorus was then measured with the ascorbic acid procedure. The second digestion was done by the procedure used for determining total nitrogen which involves persulfate digestion in an alkaline environment. The total nitrogen digestion procedure followed by phosphorus determination provided results similar to those obtained in the standard persulfate digestion for phosphorus. The slope of the regression line did not differ from 1.0 (P < 0.05) and the Y intercept did not differ from 0 (P < 0.05). Spike recovery averaged 99.1% (range 85–112%) in the total nitrogen digestion procedure; it averaged 98.4% (range 88–113%) in the standard total phosphorus digestion. The results of this investigation indicated that a single digestion can be used to obtain a digest suitable for measurements of total nitrogen and total phosphorus.
Key concepts: Digestion (alchemy), Phosphorus, Nitrogen, Animal science, Environmental chemistry, Chemistry, Biology, Chromatography