1992Journal of Clinical MicrobiologyOpen access

Multicenter evaluation of five commercial rubella virus immunoglobulin G kits which report in international units per milliliter

Wayne Dimech, A Bettoli, Debbie Eckert, Barbara H. Francis, John Hamblin, Tovah Kerr, Christine Ryan, I J Skurrie

Open full text 23 citations

Abstract

In a multicenter study, the consistency of international units expressed by five commercially available rubella virus immunoglobulin G kits was evaluated. The linearity and within-run and between-run precision were determined for each kit. All kits demonstrated good linearity and had within-run and between-run precision coefficients of variation ranging from 5.1 to 21.7% and from 9.5 to 51.0%, respectively. To compare the international units expressed, the results from 40 samples tested in duplicate were compared with the results of a reference enzyme immunoassay calibrated with World Health Organization international standard serum and a hemagglutination inhibition test. The results of the kits were plotted against those of the reference tests, and linear regression analysis was applied. The Pearson correlation coefficient ranged from 0.64 to 0.75 when the commercial kit results were compared with those of the reference enzyme immunoassay, indicating only a moderate degree of correlation. Therefore, the international units expressed by the commercial kits are insufficiently consistent to be of practical use in diagnostic clinical microbiology.

Open-access reader

About this research paper

What this paper is about

In a multicenter study, the consistency of international units expressed by five commercially available rubella virus immunoglobulin G kits was evaluated. The linearity and within-run and between-run precision were determined for each kit. All kits demonstrated good linearity and had within-run and between-run precision coefficients of variation ranging from 5.1 to 21.7% and from 9.5 to 51.0%, respectively. To compare the international units expressed, the results from 40 samples tested in duplicate were compared with the results of a reference enzyme immunoassay calibrated with World Health Organization international standard serum and a hemagglutination inhibition test. The results of the kits were plotted against those of the reference tests, and linear regression analysis was applied. The Pearson correlation coefficient ranged from 0.64 to 0.75 when the commercial kit results were compared with those of the reference enzyme immunoassay, indicating only a moderate degree of correlation. Therefore, the international units expressed by the commercial kits are insufficiently consistent to be of practical use in diagnostic clinical microbiology.

Why it matters

OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In a multicenter study, the consistency of international units expressed by five commercially available rubella virus immunoglobulin G kits was evaluated. The linearity and within-run and between-run precision were determined for each kit. All kits demonstrated good linearity and had within-run and between-run precision coefficients of variation ranging from 5.1 to 21.7% and from 9.5 to 51.0%, respectively. To compare the international units expressed, the results from 40 samples tested in duplicate were compared with the results of a reference enzyme immunoassay calibrated with World Health Organization international standard serum and a hemagglutination inhibition test. The results of the kits were plotted against those of the reference tests, and linear regression analysis was applied. The Pearson correlation coefficient ranged from 0.64 to 0.75 when the commercial kit results were compared with those of the reference enzyme immunoassay, indicating only a moderate degree of correlation. Therefore, the international units expressed by the commercial kits are insufficiently consistent to be of practical use in diagnostic clinical microbiology.

Key concepts: Immunoassay, Rubella, Coefficient of variation, Multicenter study, Repeatability, Liter, Rubella virus, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Multicenter evaluation of five commercial rubella virus immunoglobulin G kits which report in international units per milliliter — Research Paper | ScholarLens