The role of HbA1c as a screening and diagnostic test for diabetes mellitus in Ankara
Zeynep Giniş, Gülfer Öztürk, Rana Sırmalı, Ali Yalçındağ, Yakup Dülgeroğlu, Tuncay Delibaşı, Namık Delibaş
Abstract
Open-access reader
Zeynep Giniş, Gülfer Öztürk, Rana Sırmalı, Ali Yalçındağ, Yakup Dülgeroğlu, Tuncay Delibaşı, Namık Delibaş
Abstract
Open-access reader
This study investigated the value of HbA1c as a screening and diagnostic test for diabetes mellitus (DM) in high-risk Turkish individuals. Materials and methods: A total of 295 participants were successfully screened. Patients were divided into 4 groups based on their oral glucose tolerance test results, according to criteria put forth by the American Diabetes Association; 120 (40.7%) had normoglycemia, 44 (14.9%) had DM, 62 (21%) had impaired fasting glucose, and 69 (23.4%) had impaired glucose tolerance. Results: With a cut-off value for the diagnosis of DM of 6.1%, HbA1c had a sensitivity of 81.8% and a specificity of 80%, with positive and negative predictive values of 80.2% and 81.05%, respectively. A sensitivity of 56.8% and a specificity of 89.2% were calculated for a cut-off value of 6.5%. Both fasting plasma glucose and 2-h plasma glucose levels were found to correlate moderately with HbA1c levels (r = 0.47, P = 0.001 and r = 0.52, P = 0.000, respectively). Conclusion: The results of our observations suggest that HbA1c could be used to make a diagnosis of DM in the Turkish population. However, further studies are needed to determine the most accurate cut-off value. Standardization of HbA1c assays used worldwide is also of great importance.
OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
This study investigated the value of HbA1c as a screening and diagnostic test for diabetes mellitus (DM) in high-risk Turkish individuals. Materials and methods: A total of 295 participants were successfully screened. Patients were divided into 4 groups based on their oral glucose tolerance test results, according to criteria put forth by the American Diabetes Association; 120 (40.7%) had normoglycemia, 44 (14.9%) had DM, 62 (21%) had impaired fasting glucose, and 69 (23.4%) had impaired glucose tolerance. Results: With a cut-off value for the diagnosis of DM of 6.1%, HbA1c had a sensitivity of 81.8% and a specificity of 80%, with positive and negative predictive values of 80.2% and 81.05%, respectively. A sensitivity of 56.8% and a specificity of 89.2% were calculated for a cut-off value of 6.5%. Both fasting plasma glucose and 2-h plasma glucose levels were found to correlate moderately with HbA1c levels (r = 0.47, P = 0.001 and r = 0.52, P = 0.000, respectively). Conclusion: The results of our observations suggest that HbA1c could be used to make a diagnosis of DM in the Turkish population. However, further studies are needed to determine the most accurate cut-off value. Standardization of HbA1c assays used worldwide is also of great importance.
Key concepts: Medicine, Diabetes mellitus, Internal medicine, Turkish population, Plasma glucose, Impaired glucose tolerance, Glucose tolerance test, Predictive value