Simultaneous determination of chlorpheniramine and pseudoephedrine in human plasma by liquid chromatography–tandem mass spectrometry
Xiaoyan Chen, Yong Zhang, Dafang Zhong
Abstract
Xiaoyan Chen, Yong Zhang, Dafang Zhong
Abstract
A sensitive and specific procedure for simultaneous quantitation of chlorpheniramine and pseudoephedrine in human plasma has been developed and validated. Analytes were extracted from plasma samples by liquid-liquid extraction, separated on a Diamonsil C18 column (250 x 4.6 mm i.d.) and detected by tandem mass spectrometry with an atmospheric pressure chemical ionization interface. Diphenhydramine was used as the internal standard. The method has a lower limit of quantitation of 0.2 and 2.0 ng/mL for chlorpheniramine and pseudoephedrine, respectively. The intra- and inter-day relative standard deviation, calculated from quality control (QC) samples were below 4.3% for chlorpheniramine and below 9.5% for pseudoephedrine. The inter-day relative error as determined from QC samples was within 4.7% for each analyte. The overall extraction recoveries of chlorpheniramine and pseudoephedrine were 77 and 61% on average, respectively. The method was successfully applied to pharmaockinetic study of chlorpheniramine and pseudoephedrine in volunteers receiving formulations containing 4 mg of chlorpheniramine maleate and 60 mg of pseudoephedrine hydrochloride.
OpenAlex reports 37 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A sensitive and specific procedure for simultaneous quantitation of chlorpheniramine and pseudoephedrine in human plasma has been developed and validated. Analytes were extracted from plasma samples by liquid-liquid extraction, separated on a Diamonsil C18 column (250 x 4.6 mm i.d.) and detected by tandem mass spectrometry with an atmospheric pressure chemical ionization interface. Diphenhydramine was used as the internal standard. The method has a lower limit of quantitation of 0.2 and 2.0 ng/mL for chlorpheniramine and pseudoephedrine, respectively. The intra- and inter-day relative standard deviation, calculated from quality control (QC) samples were below 4.3% for chlorpheniramine and below 9.5% for pseudoephedrine. The inter-day relative error as determined from QC samples was within 4.7% for each analyte. The overall extraction recoveries of chlorpheniramine and pseudoephedrine were 77 and 61% on average, respectively. The method was successfully applied to pharmaockinetic study of chlorpheniramine and pseudoephedrine in volunteers receiving formulations containing 4 mg of chlorpheniramine maleate and 60 mg of pseudoephedrine hydrochloride.
Key concepts: Pseudoephedrine, Chemistry, Chromatography, Chlorpheniramine Maleate, Nasal decongestant, Detection limit, Analyte, Extraction (chemistry)