Experimental performance of an automobile air conditioning system using a variable capacity compressor for two different types of expansion devices
Alpaslan Alkan, Murat Hoşöz
Abstract
Alpaslan Alkan, Murat Hoşöz
Abstract
An experimental R134a automotive air conditioning (AAC) system with a variable capacity compressor has been developed and equipped with various mechanical instruments. The system has the capability of using both a thermostatic expansion valve (TXV) and an orifice tube (OT) as an expansion device. The system has been tested by varying the compressor speed and temperatures of the air streams entering the condenser (Tcond,ai) and evaporator (Tevap,ai). Using experimental data, the performance parameters of the AAC system for TXV and OT operations have been evaluated. The results show that the cooling capacity usually increases with the compressor speed. However, the exergy destruction in the system also increases and the coefficient of performance (COP) decreases with the compressor speed. The cooling capacity and COP decrease on rising Tcond,ai, while they increase on rising Tevap,ai. The TXV operation usually yields slightly higher cooling capacity and COP and lower exergy destruction compared with OT operation.
OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
An experimental R134a automotive air conditioning (AAC) system with a variable capacity compressor has been developed and equipped with various mechanical instruments. The system has the capability of using both a thermostatic expansion valve (TXV) and an orifice tube (OT) as an expansion device. The system has been tested by varying the compressor speed and temperatures of the air streams entering the condenser (Tcond,ai) and evaporator (Tevap,ai). Using experimental data, the performance parameters of the AAC system for TXV and OT operations have been evaluated. The results show that the cooling capacity usually increases with the compressor speed. However, the exergy destruction in the system also increases and the coefficient of performance (COP) decreases with the compressor speed. The cooling capacity and COP decrease on rising Tcond,ai, while they increase on rising Tevap,ai. The TXV operation usually yields slightly higher cooling capacity and COP and lower exergy destruction compared with OT operation.
Key concepts: Thermal expansion valve, Gas compressor, Cooling capacity, Condenser (optics), Evaporator, Coefficient of performance, Air conditioning, Engineering