Determination of Steroids in Human Urine by Micellar Liquid Chromatography
Zuliang Chen, ShaoFang Wang
Abstract
Zuliang Chen, ShaoFang Wang
Abstract
A simple and sensitive method for the determination of steroids using micellar liquid chromatography is described. The steroids, including hydroxycorticosterone. corticosterone, northisterone, testosterone, mexdroprogesterone acetate and progesterone, were separated by reversed-phase using a micelles mobile phase following UV detection at 245 nm. The parameters affecting retention of the test solutes such as the concentration of sodium dodecyl sulfate (SDS) and n-butanol-1 in the mobile phase were investigated. It was found that the retention of the solutes was dependent on the composition of mobile phase. The linear calibration plots range from 0.1 to 10 μg ml−1 in mobile phase containing 5.0 × 10−2 mol l−1 SDS/9 % n-butanol-1 at pH 6.0, and the detection limit in order of 0.1 μg ml−1 was obtained. The proposed method was used for the determination of steroids in urine using direct injection of samples without previous treatment.
OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A simple and sensitive method for the determination of steroids using micellar liquid chromatography is described. The steroids, including hydroxycorticosterone. corticosterone, northisterone, testosterone, mexdroprogesterone acetate and progesterone, were separated by reversed-phase using a micelles mobile phase following UV detection at 245 nm. The parameters affecting retention of the test solutes such as the concentration of sodium dodecyl sulfate (SDS) and n-butanol-1 in the mobile phase were investigated. It was found that the retention of the solutes was dependent on the composition of mobile phase. The linear calibration plots range from 0.1 to 10 μg ml−1 in mobile phase containing 5.0 × 10−2 mol l−1 SDS/9 % n-butanol-1 at pH 6.0, and the detection limit in order of 0.1 μg ml−1 was obtained. The proposed method was used for the determination of steroids in urine using direct injection of samples without previous treatment.
Key concepts: Chemistry, Chromatography, Micellar liquid chromatography, Sodium dodecyl sulfate, Detection limit, Micelle, Urine, Phase (matter)