1987•Clinical Chemistry and Laboratory Medicine (CCLM)Open access

Initial Results with a Commercial Luminescence Enhanced Enzyme Immunoassay for the Determination of Carcinoembryonic Antigen (CEA) in Body Fluids

William Graham Wood

Open full text 4 citations

Abstract

A commercially available luminescence enhanced enzyme immunoassay (Amerlite--Amersham International) for carcinoembryonic antigen (CEA) was compared with an established enzyme immunoassay (Monoclonal 1-step Assay--Abbott Laboratories). A reference range for healthy blood donors (n = 272) was established for both kits. The blood donors were not separated into smokers and non-smokers, but were excluded from the reference group if they showed abnormal aminotransferase or gamma-glutamyltranspeptidase serum values. Twenty eight donors were excluded in this way. The test group consisted of 130 known tumour patients, and included pre- and post-operative serum samples. Normal and elevated CEA values were present. All sera were negative for HBsAg, anti-HBsAg and anti-HIV as determined with commercial enzyme immunoassays used routinely in the blood bank. The luminescence enhanced immunoassay gave rise to a reference range (95% confidence limits) of less than 3.91 micrograms/l in comparison with the enzyme immunoassay, which had a reference range of less than 4.12 micrograms/l. The proportion of elevated values in the tumour patient group was 37/130 for the luminescence enhanced enzyme immunoassay and 28/130 for the enzyme immunoassay. The correlation of values from both methods in the blood donor group was good (r = 0.771, n = 272). The CEA levels found in the tumour patient group differed significantly when measured in both kits (Wilcoxon matched-pair signed rank test--c-alpha = -6.52, p less than 0.01, n = 130), the Amersham kit giving the higher results (median values--Abbott 2.35 micrograms/l, Amersham 2.50 micrograms/l).(ABSTRACT TRUNCATED AT 250 WORDS)

Open-access reader

About this research paper

What this paper is about

A commercially available luminescence enhanced enzyme immunoassay (Amerlite--Amersham International) for carcinoembryonic antigen (CEA) was compared with an established enzyme immunoassay (Monoclonal 1-step Assay--Abbott Laboratories). A reference range for healthy blood donors (n = 272) was established for both kits. The blood donors were not separated into smokers and non-smokers, but were excluded from the reference group if they showed abnormal aminotransferase or gamma-glutamyltranspeptidase serum values. Twenty eight donors were excluded in this way. The test group consisted of 130 known tumour patients, and included pre- and post-operative serum samples. Normal and elevated CEA values were present. All sera were negative for HBsAg, anti-HBsAg and anti-HIV as determined with commercial enzyme immunoassays used routinely in the blood bank. The luminescence enhanced immunoassay gave rise to a reference range (95% confidence limits) of less than 3.91 micrograms/l in comparison with the enzyme immunoassay, which had a reference range of less than 4.12 micrograms/l. The proportion of elevated values in the tumour patient group was 37/130 for the luminescence enhanced enzyme immunoassay and 28/130 for the enzyme immunoassay. The correlation of values from both methods in the blood donor group was good (r = 0.771, n = 272). The CEA levels found in the tumour patient group differed significantly when measured in both kits (Wilcoxon matched-pair signed rank test--c-alpha = -6.52, p less than 0.01, n = 130), the Amersham kit giving the higher results (median values--Abbott 2.35 micrograms/l, Amersham 2.50 micrograms/l).(ABSTRACT TRUNCATED AT 250 WORDS)

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A commercially available luminescence enhanced enzyme immunoassay (Amerlite--Amersham International) for carcinoembryonic antigen (CEA) was compared with an established enzyme immunoassay (Monoclonal 1-step Assay--Abbott Laboratories). A reference range for healthy blood donors (n = 272) was established for both kits. The blood donors were not separated into smokers and non-smokers, but were excluded from the reference group if they showed abnormal aminotransferase or gamma-glutamyltranspeptidase serum values. Twenty eight donors were excluded in this way. The test group consisted of 130 known tumour patients, and included pre- and post-operative serum samples. Normal and elevated CEA values were present. All sera were negative for HBsAg, anti-HBsAg and anti-HIV as determined with commercial enzyme immunoassays used routinely in the blood bank. The luminescence enhanced immunoassay gave rise to a reference range (95% confidence limits) of less than 3.91 micrograms/l in comparison with the enzyme immunoassay, which had a reference range of less than 4.12 micrograms/l. The proportion of elevated values in the tumour patient group was 37/130 for the luminescence enhanced enzyme immunoassay and 28/130 for the enzyme immunoassay. The correlation of values from both methods in the blood donor group was good (r = 0.771, n = 272). The CEA levels found in the tumour patient group differed significantly when measured in both kits (Wilcoxon matched-pair signed rank test--c-alpha = -6.52, p less than 0.01, n = 130), the Amersham kit giving the higher results (median values--Abbott 2.35 micrograms/l, Amersham 2.50 micrograms/l).(ABSTRACT TRUNCATED AT 250 WORDS)

Key concepts: Carcinoembryonic antigen, Immunoassay, Reference range, Medicine, HBsAg, Radioimmunoassay, Chemistry, Molecular biology

Related papers

Back to paper searchBrowse research topicsOriginal source
Initial Results with a Commercial Luminescence Enhanced Enzyme Immunoassay for the Determination of Carcinoembryonic Antigen (CEA) in Body Fluids — Research Paper | ScholarLens