2007•Unpublished venueRequires access

Optimization of a Thermoelectric Cooler-Heat Sink Combination for Active Processor Cooling

Mohd. Hafiz Hasan, Kok Chuan Toh

Open publisher page 16 citations

Abstract

This study was carried out to explore the possibility of extending the limits of air cooling by using a thermoelectric cooler (TEC) enhanced cooling system which consists of a TEC used in conjunction with a fan-cooled heat sink to cool a processor. A systematic methodology for characterizing and comparing the performance of the TEC enhanced system with that of a heat sink only system is proposed. The performance of each cooling system is characterized using two criteria: its ability to produce lower junction temperatures (Tf) and its ability to allow the use of larger heat sink thermal resistances (Rhs), both for specified heat dissipation requirements. The effect of variations in the coefficient of performance (COP) of the TEC on the TEC enhanced system's performance is also explored, followed by identification of the conditions under which the system will perform better than the heat sink only system and vice versa. Both cooling systems are modeled using one dimensional thermal resistance networks, after which iterative algorithms are derived to determine their performance. Using the method proposed, the performance of an off-the- shelf TEC used together with a fan-cooled extruded aluminum heat sink in cooling a Pentium processor package is analyzed and compared with the performance of only the heat sink. Results revealed that the TEC enhanced system favors low heat loads and small RHS to produce lower Tfthan the heat sink only system, while it favors low heat loads and low Tfto allow the use of larger RHS. The results also revealed a trade-off for increasing the COP of the TEC, where the TEC enhanced system's performance in terms of the two criteria degrades as its COP is increased.

About this research paper

What this paper is about

This study was carried out to explore the possibility of extending the limits of air cooling by using a thermoelectric cooler (TEC) enhanced cooling system which consists of a TEC used in conjunction with a fan-cooled heat sink to cool a processor. A systematic methodology for characterizing and comparing the performance of the TEC enhanced system with that of a heat sink only system is proposed. The performance of each cooling system is characterized using two criteria: its ability to produce lower junction temperatures (Tf) and its ability to allow the use of larger heat sink thermal resistances (Rhs), both for specified heat dissipation requirements. The effect of variations in the coefficient of performance (COP) of the TEC on the TEC enhanced system's performance is also explored, followed by identification of the conditions under which the system will perform better than the heat sink only system and vice versa. Both cooling systems are modeled using one dimensional thermal resistance networks, after which iterative algorithms are derived to determine their performance. Using the method proposed, the performance of an off-the- shelf TEC used together with a fan-cooled extruded aluminum heat sink in cooling a Pentium processor package is analyzed and compared with the performance of only the heat sink. Results revealed that the TEC enhanced system favors low heat loads and small RHS to produce lower Tfthan the heat sink only system, while it favors low heat loads and low Tfto allow the use of larger RHS. The results also revealed a trade-off for increasing the COP of the TEC, where the TEC enhanced system's performance in terms of the two criteria degrades as its COP is increased.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study was carried out to explore the possibility of extending the limits of air cooling by using a thermoelectric cooler (TEC) enhanced cooling system which consists of a TEC used in conjunction with a fan-cooled heat sink to cool a processor. A systematic methodology for characterizing and comparing the performance of the TEC enhanced system with that of a heat sink only system is proposed. The performance of each cooling system is characterized using two criteria: its ability to produce lower junction temperatures (Tf) and its ability to allow the use of larger heat sink thermal resistances (Rhs), both for specified heat dissipation requirements. The effect of variations in the coefficient of performance (COP) of the TEC on the TEC enhanced system's performance is also explored, followed by identification of the conditions under which the system will perform better than the heat sink only system and vice versa. Both cooling systems are modeled using one dimensional thermal resistance networks, after which iterative algorithms are derived to determine their performance. Using the method proposed, the performance of an off-the- shelf TEC used together with a fan-cooled extruded aluminum heat sink in cooling a Pentium processor package is analyzed and compared with the performance of only the heat sink. Results revealed that the TEC enhanced system favors low heat loads and small RHS to produce lower Tfthan the heat sink only system, while it favors low heat loads and low Tfto allow the use of larger RHS. The results also revealed a trade-off for increasing the COP of the TEC, where the TEC enhanced system's performance in terms of the two criteria degrades as its COP is increased.

Key concepts: TEC, Heat sink, Thermoelectric cooling, Coefficient of performance, Active cooling, Water cooling, Thermoelectric effect, Thermal resistance

Related papers

Back to paper searchBrowse research topicsOriginal source
Optimization of a Thermoelectric Cooler-Heat Sink Combination for Active Processor Cooling — Research Paper | ScholarLens