2011Rapid Communications in Mass SpectrometryRequires access

Comparison of stable‐isotope labeling with amino acids in cell culture and spectral counting for relative quantification of protein expression

Timothy S. Collier, Shan M. Randall, Prasenjit Sarkar, Balaji M. Rao, Ralph A. Dean, David C. Muddiman

Open publisher page 35 citations

Abstract

Protein quantification is one of the principal goals of mass spectrometry (MS)-based proteomics, and many strategies exist to achieve it. Several approaches involve the incorporation of a stable-isotope label using either chemical derivatization, enzymatically catalyzed incorporation of (18)O, or metabolic labeling in a cell or tissue culture. These techniques can be cost or time prohibitive or not amenable to the biological system of interest. Label-free techniques including those utilizing integrated ion abundance and spectral counting offer an alternative to stable-isotope-based methodologies. Herein, we present the comparison of stable-isotope labeling of amino acids in cell culture (SILAC) with spectral counting for the quantification of human embryonic stem cells as they differentiate toward the trophectoderm at three time points. Our spectral counting experimental strategy resulted in the identification of 2641 protein groups across three time points with an average sequence coverage of 30.3%, of which 1837 could be quantified with more than five spectral counts. SILAC quantification was able to identify 1369 protein groups with an average coverage of 24.7%, of which 1027 could be quantified across all time points. Within this context we further explore the capacity of each strategy for proteome coverage, variation in quantification, and the relative sensitivity of each technique to the detection of change in relative protein expression.

About this research paper

What this paper is about

Protein quantification is one of the principal goals of mass spectrometry (MS)-based proteomics, and many strategies exist to achieve it. Several approaches involve the incorporation of a stable-isotope label using either chemical derivatization, enzymatically catalyzed incorporation of (18)O, or metabolic labeling in a cell or tissue culture. These techniques can be cost or time prohibitive or not amenable to the biological system of interest. Label-free techniques including those utilizing integrated ion abundance and spectral counting offer an alternative to stable-isotope-based methodologies. Herein, we present the comparison of stable-isotope labeling of amino acids in cell culture (SILAC) with spectral counting for the quantification of human embryonic stem cells as they differentiate toward the trophectoderm at three time points. Our spectral counting experimental strategy resulted in the identification of 2641 protein groups across three time points with an average sequence coverage of 30.3%, of which 1837 could be quantified with more than five spectral counts. SILAC quantification was able to identify 1369 protein groups with an average coverage of 24.7%, of which 1027 could be quantified across all time points. Within this context we further explore the capacity of each strategy for proteome coverage, variation in quantification, and the relative sensitivity of each technique to the detection of change in relative protein expression.

Why it matters

OpenAlex reports 35 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Protein quantification is one of the principal goals of mass spectrometry (MS)-based proteomics, and many strategies exist to achieve it. Several approaches involve the incorporation of a stable-isotope label using either chemical derivatization, enzymatically catalyzed incorporation of (18)O, or metabolic labeling in a cell or tissue culture. These techniques can be cost or time prohibitive or not amenable to the biological system of interest. Label-free techniques including those utilizing integrated ion abundance and spectral counting offer an alternative to stable-isotope-based methodologies. Herein, we present the comparison of stable-isotope labeling of amino acids in cell culture (SILAC) with spectral counting for the quantification of human embryonic stem cells as they differentiate toward the trophectoderm at three time points. Our spectral counting experimental strategy resulted in the identification of 2641 protein groups across three time points with an average sequence coverage of 30.3%, of which 1837 could be quantified with more than five spectral counts. SILAC quantification was able to identify 1369 protein groups with an average coverage of 24.7%, of which 1027 could be quantified across all time points. Within this context we further explore the capacity of each strategy for proteome coverage, variation in quantification, and the relative sensitivity of each technique to the detection of change in relative protein expression.

Key concepts: Stable isotope labeling by amino acids in cell culture, Chemistry, Quantitative proteomics, Derivatization, Proteome, Isotopic labeling, Label-free quantification, Mass spectrometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of stable‐isotope labeling with amino acids in cell culture and spectral counting for relative quantification of protein expression — Research Paper | ScholarLens