1996RadiologyRequires access

Early stage melanoma: lymphoscintigraphy, reproducibility of sentinel node detection, and effectiveness of the intraoperative gamma probe.

A. Mudun, D. Murray, S C Herda, Dennis Eshima, L A Shattuck, John Vansant, Andrew Taylor, Naomi P. Alazraki

Open publisher page 118 citations

Abstract

PURPOSE: To assess the influence of lymphoscintigraphic and intraoperative gamma probe findings on the surgical management of melanoma and to test reproducibility of lymphoscintigraphic findings. MATERIALS AND METHODS: After lymphoscintigraphic identification of the sentinel node, intraoperative gamma probe localization and sentinel lymph node excision were performed in 25 patients. To assess reproducibility, 13 patients underwent lymphoscintigraphy twice within 2-17 days. A modified preparation of technetium-99m sulfur colloid with smaller particles than routinely obtained was injected intradermally around the lesion. Dynamic flow images were obtained at 10 seconds per frame followed by a series of static images obtained every 5 minutes for 30 minutes. RESULTS: A sentinel node was identified in all patients. In eight patients, multiple drainage pathways were seen and surgical management was changed. In 11 of the 13 who underwent lymphoscintigraphy twice, sentinel node identification was reproducible. CONCLUSION: Lymphoscintigraphy is reproducible in detection of the sentinel node and with the surgical probe helps effectively guide surgical management.

About this research paper

What this paper is about

PURPOSE: To assess the influence of lymphoscintigraphic and intraoperative gamma probe findings on the surgical management of melanoma and to test reproducibility of lymphoscintigraphic findings. MATERIALS AND METHODS: After lymphoscintigraphic identification of the sentinel node, intraoperative gamma probe localization and sentinel lymph node excision were performed in 25 patients. To assess reproducibility, 13 patients underwent lymphoscintigraphy twice within 2-17 days. A modified preparation of technetium-99m sulfur colloid with smaller particles than routinely obtained was injected intradermally around the lesion. Dynamic flow images were obtained at 10 seconds per frame followed by a series of static images obtained every 5 minutes for 30 minutes. RESULTS: A sentinel node was identified in all patients. In eight patients, multiple drainage pathways were seen and surgical management was changed. In 11 of the 13 who underwent lymphoscintigraphy twice, sentinel node identification was reproducible. CONCLUSION: Lymphoscintigraphy is reproducible in detection of the sentinel node and with the surgical probe helps effectively guide surgical management.

Why it matters

OpenAlex reports 118 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To assess the influence of lymphoscintigraphic and intraoperative gamma probe findings on the surgical management of melanoma and to test reproducibility of lymphoscintigraphic findings. MATERIALS AND METHODS: After lymphoscintigraphic identification of the sentinel node, intraoperative gamma probe localization and sentinel lymph node excision were performed in 25 patients. To assess reproducibility, 13 patients underwent lymphoscintigraphy twice within 2-17 days. A modified preparation of technetium-99m sulfur colloid with smaller particles than routinely obtained was injected intradermally around the lesion. Dynamic flow images were obtained at 10 seconds per frame followed by a series of static images obtained every 5 minutes for 30 minutes. RESULTS: A sentinel node was identified in all patients. In eight patients, multiple drainage pathways were seen and surgical management was changed. In 11 of the 13 who underwent lymphoscintigraphy twice, sentinel node identification was reproducible. CONCLUSION: Lymphoscintigraphy is reproducible in detection of the sentinel node and with the surgical probe helps effectively guide surgical management.

Key concepts: Medicine, Gamma probe, Sentinel node, Sentinel lymph node, Reproducibility, Stage (stratigraphy), Lymph node, Technetium

Related papers

Back to paper searchBrowse research topicsOriginal source
Early stage melanoma: lymphoscintigraphy, reproducibility of sentinel node detection, and effectiveness of the intraoperative gamma probe. — Research Paper | ScholarLens