2009Astronomy and AstrophysicsOpen access

Comparison between the luminosity functions of X-ray and [OIII] selected AGN

I. Georgantopoulos, A. Akylas

Open full text 26 citations

Abstract

We investigate claims according to which the X-ray selection of AGN is not as efficient compared to that based on [OIII] selection because of the effects of X-ray absorption. We construct the predicted X-ray luminosity function both for all Seyferts as well as separately for Seyfert-1 and Seyfert-2 type galaxies, by combining the optical AGN [OIII] luminosity functions computed in SDSS with the corresponding LX-L[OIII] relations. These relations are derived from XMM-Newton observations of all Seyfert galaxies in the Palomar spectroscopic sample of nearby galaxies after a correction for X-ray absorption and optical reddening. We compare the predicted X-ray luminosity functions with those actually observed in the local Universe by HEAO-1, RXTE as well as INTEGRAL. The last luminosity function is obtained in the 17–60 keV region and thus is not affected by absorption even in the case of Compton-thick sources. In the common luminosity regions, the optically and X-ray selected Seyfert galaxies show reasonable agreement. We thus find no evidence that the [OIII] selection provides a more robust tracer of powerful AGN compared to the X-ray. Still, the optical selection probes less luminous Seyferts compared to the current X-ray surveys. These low luminosity levels, are populated by a large number of X-ray unobscured Seyfert-2 galaxies.

Open-access reader

About this research paper

What this paper is about

We investigate claims according to which the X-ray selection of AGN is not as efficient compared to that based on [OIII] selection because of the effects of X-ray absorption. We construct the predicted X-ray luminosity function both for all Seyferts as well as separately for Seyfert-1 and Seyfert-2 type galaxies, by combining the optical AGN [OIII] luminosity functions computed in SDSS with the corresponding LX-L[OIII] relations. These relations are derived from XMM-Newton observations of all Seyfert galaxies in the Palomar spectroscopic sample of nearby galaxies after a correction for X-ray absorption and optical reddening. We compare the predicted X-ray luminosity functions with those actually observed in the local Universe by HEAO-1, RXTE as well as INTEGRAL. The last luminosity function is obtained in the 17–60 keV region and thus is not affected by absorption even in the case of Compton-thick sources. In the common luminosity regions, the optically and X-ray selected Seyfert galaxies show reasonable agreement. We thus find no evidence that the [OIII] selection provides a more robust tracer of powerful AGN compared to the X-ray. Still, the optical selection probes less luminous Seyferts compared to the current X-ray surveys. These low luminosity levels, are populated by a large number of X-ray unobscured Seyfert-2 galaxies.

Why it matters

OpenAlex reports 26 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We investigate claims according to which the X-ray selection of AGN is not as efficient compared to that based on [OIII] selection because of the effects of X-ray absorption. We construct the predicted X-ray luminosity function both for all Seyferts as well as separately for Seyfert-1 and Seyfert-2 type galaxies, by combining the optical AGN [OIII] luminosity functions computed in SDSS with the corresponding LX-L[OIII] relations. These relations are derived from XMM-Newton observations of all Seyfert galaxies in the Palomar spectroscopic sample of nearby galaxies after a correction for X-ray absorption and optical reddening. We compare the predicted X-ray luminosity functions with those actually observed in the local Universe by HEAO-1, RXTE as well as INTEGRAL. The last luminosity function is obtained in the 17–60 keV region and thus is not affected by absorption even in the case of Compton-thick sources. In the common luminosity regions, the optically and X-ray selected Seyfert galaxies show reasonable agreement. We thus find no evidence that the [OIII] selection provides a more robust tracer of powerful AGN compared to the X-ray. Still, the optical selection probes less luminous Seyferts compared to the current X-ray surveys. These low luminosity levels, are populated by a large number of X-ray unobscured Seyfert-2 galaxies.

Key concepts: Physics, Astrophysics, Luminosity, Luminosity function, Galaxy, Active galactic nucleus, Universe, X-ray

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison between the luminosity functions of X-ray and [OIII] selected AGN — Research Paper | ScholarLens