2006IEEE Transactions on Energy ConversionRequires access

Performance Assessment of Active Frequency Drifting Islanding Detection Methods

Luiz A. C. Lopes, Hua Sun

Open publisher page 434 citations

Abstract

Islanding detection is a mandatory feature for grid-connected inverters. The effectiveness of passive islanding detection methods (IDMs) is usually demonstrated by means of nondetection zones (NDZs) represented in a power mismatch space (/spl Delta/P versus /spl Delta/Q). Active frequency drifting IDMs have been shown to provide improved performance but their theoretical NDZ cannot be described in the /spl Delta/P versus /spl Delta/Q space for a general RLC load. This paper shows that a load parameter space based on the values of the quality factor and resonant frequency of the local load (Q/sub f/ versus f/sub 0/) can be used in these cases. It employs a single curve to represent the NDZ of frequency drifting IDMs for any RLC loads. Equations that represent NDZs of three common active IDMs in the Q/sub f/ versus f/sub 0/ load parameter space are derived and it is shown that the slip mode frequency shift and the Sandia frequency shift IDMs can be designed to guarantee islanding detection for equivalent RLC loads with a quality factor smaller than a design value. The accuracy of the NDZs is verified with simulation and experimental results.

About this research paper

What this paper is about

Islanding detection is a mandatory feature for grid-connected inverters. The effectiveness of passive islanding detection methods (IDMs) is usually demonstrated by means of nondetection zones (NDZs) represented in a power mismatch space (/spl Delta/P versus /spl Delta/Q). Active frequency drifting IDMs have been shown to provide improved performance but their theoretical NDZ cannot be described in the /spl Delta/P versus /spl Delta/Q space for a general RLC load. This paper shows that a load parameter space based on the values of the quality factor and resonant frequency of the local load (Q/sub f/ versus f/sub 0/) can be used in these cases. It employs a single curve to represent the NDZ of frequency drifting IDMs for any RLC loads. Equations that represent NDZs of three common active IDMs in the Q/sub f/ versus f/sub 0/ load parameter space are derived and it is shown that the slip mode frequency shift and the Sandia frequency shift IDMs can be designed to guarantee islanding detection for equivalent RLC loads with a quality factor smaller than a design value. The accuracy of the NDZs is verified with simulation and experimental results.

Why it matters

OpenAlex reports 434 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Islanding detection is a mandatory feature for grid-connected inverters. The effectiveness of passive islanding detection methods (IDMs) is usually demonstrated by means of nondetection zones (NDZs) represented in a power mismatch space (/spl Delta/P versus /spl Delta/Q). Active frequency drifting IDMs have been shown to provide improved performance but their theoretical NDZ cannot be described in the /spl Delta/P versus /spl Delta/Q space for a general RLC load. This paper shows that a load parameter space based on the values of the quality factor and resonant frequency of the local load (Q/sub f/ versus f/sub 0/) can be used in these cases. It employs a single curve to represent the NDZ of frequency drifting IDMs for any RLC loads. Equations that represent NDZs of three common active IDMs in the Q/sub f/ versus f/sub 0/ load parameter space are derived and it is shown that the slip mode frequency shift and the Sandia frequency shift IDMs can be designed to guarantee islanding detection for equivalent RLC loads with a quality factor smaller than a design value. The accuracy of the NDZs is verified with simulation and experimental results.

Key concepts: Islanding, RLC circuit, Control theory (sociology), AC power, Q factor, Electronic engineering, Physics, Power (physics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Performance Assessment of Active Frequency Drifting Islanding Detection Methods — Research Paper | ScholarLens