2012•Unpublished venueRequires access

Method of obtaining the sensitive disturbances of frequency control system including AGC by analyzing the frequency-response trajectory

Yafeng Huang, Gang Mu, Long Li, Gangui Yan, Jia Liu, ZeHui Wang

Open publisher page 1 citations

Abstract

For a specific frequency control system including AGC, there were relative differences in system frequency response due to the power disturbances in different frequency. The sensitive disturbances were defined in this paper by considering the natural characteristics of frequency control system including AGC. Establishing the frequency control system model, then analyzing its transfer function is an efficient way to obtain the system frequency response characteristics. Actually, it is hard to know the detail system model and the exact system transfer function, a method of obtaining the sensitive disturbances of frequency control system including AGC was proposed, in this method, the frequency-response trajectory in the condition of step load disturbance was needed, which is easy to be satisfied. The simulation example based on a simple frequency control system including AGC was given, analysis result show the validity of this method of obtaining sensitive disturbances by analyzing the frequency-response trajectory.

About this research paper

What this paper is about

For a specific frequency control system including AGC, there were relative differences in system frequency response due to the power disturbances in different frequency. The sensitive disturbances were defined in this paper by considering the natural characteristics of frequency control system including AGC. Establishing the frequency control system model, then analyzing its transfer function is an efficient way to obtain the system frequency response characteristics. Actually, it is hard to know the detail system model and the exact system transfer function, a method of obtaining the sensitive disturbances of frequency control system including AGC was proposed, in this method, the frequency-response trajectory in the condition of step load disturbance was needed, which is easy to be satisfied. The simulation example based on a simple frequency control system including AGC was given, analysis result show the validity of this method of obtaining sensitive disturbances by analyzing the frequency-response trajectory.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

For a specific frequency control system including AGC, there were relative differences in system frequency response due to the power disturbances in different frequency. The sensitive disturbances were defined in this paper by considering the natural characteristics of frequency control system including AGC. Establishing the frequency control system model, then analyzing its transfer function is an efficient way to obtain the system frequency response characteristics. Actually, it is hard to know the detail system model and the exact system transfer function, a method of obtaining the sensitive disturbances of frequency control system including AGC was proposed, in this method, the frequency-response trajectory in the condition of step load disturbance was needed, which is easy to be satisfied. The simulation example based on a simple frequency control system including AGC was given, analysis result show the validity of this method of obtaining sensitive disturbances by analyzing the frequency-response trajectory.

Key concepts: Frequency response, Transfer function, Automatic frequency control, Control theory (sociology), Trajectory, Automatic Generation Control, Computer science, Electric power system

Related papers

Back to paper searchBrowse research topicsOriginal source
Method of obtaining the sensitive disturbances of frequency control system including AGC by analyzing the frequency-response trajectory — Research Paper | ScholarLens