A High-Performance Liquid Chromatographic Method for the Determination of Hypoxanthine, Xanthine, Uric Acid and Allantoin in Serum
R. Kock, Bert Delvoux, H. Greiling
Abstract
R. Kock, Bert Delvoux, H. Greiling
Abstract
A method was developed for the simultaneous determination of hypoxanthine, xanthine, uric acid and allantoin based on isocratic reversed-phase chromatography. This HPLC-method additionally allows the direct determination with UV-detection of inosine-5'-phosphate, uridine, thymine, orotic acid, allopurinol and oxipurinol, besides hypoxanthine, xanthine and uric acid in the same chromatographic run. Allantoin elutes in this system near the void volume and a fraction is collected covering the retention time range for this substance. After hydrolysis allantoin is converted to glyoxylate-2,4-dinitrophenylhydrazone, rechromatographed and detected at 360 nm. The coefficient of variation for this method does not exceed 5.0% for a serum concentration of 0.3 mumol/l hypoxanthine and is not greater than 5.3% for a xanthine concentration of 0.3 mumol/l serum. Recoveries were 90-110% for both hypoxanthine and xanthine. The determination of uric acid had an imprecision and inaccuracy not exceeding 1.45% in the concentration range of 103-568 mumol/l. Due to the more complex procedure required for the determination of allantoin, the coefficient of variation between days was 13.6% for a sample containing 0.8 mumol/l allantoin and the recoveries for this analyte were in the range of 86-93%. Reference ranges (mean +/- SD) determined on 171 serum samples from healthy adults were 12.7 +/- 6.6 mumol/l for hypoxanthine, 3.3 +/- 1.4 mumol/l for xanthine, and 15.7 +/- 7.9 mumol/l for allantoin. No significant age or sex dependence was observed. Uric acid concentrations were 320 +/- 55 mumol/l serum for men and 206 +/- 55 mumol/l for women.
OpenAlex reports 50 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A method was developed for the simultaneous determination of hypoxanthine, xanthine, uric acid and allantoin based on isocratic reversed-phase chromatography. This HPLC-method additionally allows the direct determination with UV-detection of inosine-5'-phosphate, uridine, thymine, orotic acid, allopurinol and oxipurinol, besides hypoxanthine, xanthine and uric acid in the same chromatographic run. Allantoin elutes in this system near the void volume and a fraction is collected covering the retention time range for this substance. After hydrolysis allantoin is converted to glyoxylate-2,4-dinitrophenylhydrazone, rechromatographed and detected at 360 nm. The coefficient of variation for this method does not exceed 5.0% for a serum concentration of 0.3 mumol/l hypoxanthine and is not greater than 5.3% for a xanthine concentration of 0.3 mumol/l serum. Recoveries were 90-110% for both hypoxanthine and xanthine. The determination of uric acid had an imprecision and inaccuracy not exceeding 1.45% in the concentration range of 103-568 mumol/l. Due to the more complex procedure required for the determination of allantoin, the coefficient of variation between days was 13.6% for a sample containing 0.8 mumol/l allantoin and the recoveries for this analyte were in the range of 86-93%. Reference ranges (mean +/- SD) determined on 171 serum samples from healthy adults were 12.7 +/- 6.6 mumol/l for hypoxanthine, 3.3 +/- 1.4 mumol/l for xanthine, and 15.7 +/- 7.9 mumol/l for allantoin. No significant age or sex dependence was observed. Uric acid concentrations were 320 +/- 55 mumol/l serum for men and 206 +/- 55 mumol/l for women.
Key concepts: Allantoin, Hypoxanthine, Xanthine, Uric acid, Chromatography, Chemistry, Inosine, High-performance liquid chromatography