2014Applied Physiology Nutrition and MetabolismOpen access

Oxygen uptake during upper body and lower body Wingate anaerobic tests

Mike Price, Christopher Beckford, Adam Dorricott, Cameron Hill, Megan Kershaw, M. Singh, Ian Michael Thornton

Open full text 17 citations

Abstract

The aim of this study was to determine the aerobic contribution to upper body and lower body Wingate Anaerobic tests (WAnT). Eight nonspecifically trained males volunteered to take part in this study. Participants undertook incremental exercise tests for peak oxygen uptake and two 30-s WAnT (habituation and experimental) for both the upper and lower body. The resistive loadings used were 0.040 and 0.075 kg·kg body mass(-1), respectively. Peak power output (PPO) and mean power output (MPO) were calculated for each WAnT. The aerobic contribution of each WAnT was assessed using breath by breath expired gas analysis. Peak oxygen uptake was lower for the upper body when compared with the lower body (P = 0.001). Similarly, PPO and MPO were greater for the lower body (both P < 0.001). Absolute oxygen uptake during the upper body WAnT was lower than for the lower body (P = 0.013), whereas relative oxygen uptake (% peak oxygen uptake) was similar (P = 0.997). The mean aerobic contribution for the upper body WAnT (43.5% ± 29.3%) was greater than for the lower body (29.4% ± 15.8%; P < 0.001). The greater aerobic contribution to the WAnT observed for the upper body in comparison with the lower body is likely due to methodological differences in upper and lower body WAnT protocols and potentially differences in anaerobic power production and exercise efficiency. The results of this study suggest that differences may exist for the aerobic contribution of upper and lower body Wingate anaerobic tests.

About this research paper

What this paper is about

The aim of this study was to determine the aerobic contribution to upper body and lower body Wingate Anaerobic tests (WAnT). Eight nonspecifically trained males volunteered to take part in this study. Participants undertook incremental exercise tests for peak oxygen uptake and two 30-s WAnT (habituation and experimental) for both the upper and lower body. The resistive loadings used were 0.040 and 0.075 kg·kg body mass(-1), respectively. Peak power output (PPO) and mean power output (MPO) were calculated for each WAnT. The aerobic contribution of each WAnT was assessed using breath by breath expired gas analysis. Peak oxygen uptake was lower for the upper body when compared with the lower body (P = 0.001). Similarly, PPO and MPO were greater for the lower body (both P < 0.001). Absolute oxygen uptake during the upper body WAnT was lower than for the lower body (P = 0.013), whereas relative oxygen uptake (% peak oxygen uptake) was similar (P = 0.997). The mean aerobic contribution for the upper body WAnT (43.5% ± 29.3%) was greater than for the lower body (29.4% ± 15.8%; P < 0.001). The greater aerobic contribution to the WAnT observed for the upper body in comparison with the lower body is likely due to methodological differences in upper and lower body WAnT protocols and potentially differences in anaerobic power production and exercise efficiency. The results of this study suggest that differences may exist for the aerobic contribution of upper and lower body Wingate anaerobic tests.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The aim of this study was to determine the aerobic contribution to upper body and lower body Wingate Anaerobic tests (WAnT). Eight nonspecifically trained males volunteered to take part in this study. Participants undertook incremental exercise tests for peak oxygen uptake and two 30-s WAnT (habituation and experimental) for both the upper and lower body. The resistive loadings used were 0.040 and 0.075 kg·kg body mass(-1), respectively. Peak power output (PPO) and mean power output (MPO) were calculated for each WAnT. The aerobic contribution of each WAnT was assessed using breath by breath expired gas analysis. Peak oxygen uptake was lower for the upper body when compared with the lower body (P = 0.001). Similarly, PPO and MPO were greater for the lower body (both P < 0.001). Absolute oxygen uptake during the upper body WAnT was lower than for the lower body (P = 0.013), whereas relative oxygen uptake (% peak oxygen uptake) was similar (P = 0.997). The mean aerobic contribution for the upper body WAnT (43.5% ± 29.3%) was greater than for the lower body (29.4% ± 15.8%; P < 0.001). The greater aerobic contribution to the WAnT observed for the upper body in comparison with the lower body is likely due to methodological differences in upper and lower body WAnT protocols and potentially differences in anaerobic power production and exercise efficiency. The results of this study suggest that differences may exist for the aerobic contribution of upper and lower body Wingate anaerobic tests.

Key concepts: Upper body, Anaerobic exercise, Wingate test, VO2 max, Lower body, Oxygen, Animal science, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Oxygen uptake during upper body and lower body Wingate anaerobic tests — Research Paper | ScholarLens