1999•Journal of Clinical PathologyOpen access

Clinical application of the Quantiplex HCV RNA 2.0 and Amplicor HCV Monitor assays for quantifying serum hepatitis C virus RNA.

Ming‐Lung Yu, Wan‐Long Chuang, S. C. Chen, Zu‐Yau Lin, Meng‐Hsuan Hsieh, Ling‐Yu Wang, Wen‐Yu Chang

Open full text 14 citations

Abstract

AIM: To compare the performance characteristics and clinical application of two different technologies for quantifying serum hepatitis C virus (HCV) RNA levels. METHODS: HCV RNA was quantified by Amplicor HCV Monitor assay (Amplicor) and Quantiplex HCV RNA 2.0 assay (bDNA-2) in 119 sera from 107 HCV infected patients. RESULTS: Both assays had similar sensitivity (79.4% for Amplicor; 86.0% for bDNA-2), acceptable coefficients of variation (5.3% in Amplicor; 2.6% in bDNA-2), and good linearity (r2 > or = 0.98). There was a positive correlation between quantification values of both methods (r = 0.683, p < 0.001). The Amplicor values were on an average 1.76 log lower than bDNA-2 results. Male subjects and HCV genotype 1b were significantly associated with higher viral load determined by Amplicor, but not with viral load measured by bDNA-2. In 70 chronic HCV infected patients treated with interferon alfa, mean (SD) pretreatment viral load in 27 complete responders (3.47 (0.84) logs for Amplicor, 5.63 (0.58) for bDNA-2) was significantly lower than in non-responders (4.43 (1.01) logs for Amplicor, 6.10 (0.67) logs for bDNA-2; p < 0.001). Cut off points of 3.9 logs for Amplicor and 5.8 logs for bDNA-2 were determined to be the best for predicting response to interferon alfa, giving acceptable sensitivity (70.4%, 74.1%), specificity (72.1%, 65.1%), and accuracy (71.4%, 68.6%), respectively. CONCLUSIONS: Both the Amplicor and bDNA-2 assays are clinically useful methods for HCV RNA quantification and are reliable for predicting the outcome of treatment, despite differences in absolute quantification values and in the correlation between HCV genotypes and viral load.

Open-access reader

About this research paper

What this paper is about

AIM: To compare the performance characteristics and clinical application of two different technologies for quantifying serum hepatitis C virus (HCV) RNA levels. METHODS: HCV RNA was quantified by Amplicor HCV Monitor assay (Amplicor) and Quantiplex HCV RNA 2.0 assay (bDNA-2) in 119 sera from 107 HCV infected patients. RESULTS: Both assays had similar sensitivity (79.4% for Amplicor; 86.0% for bDNA-2), acceptable coefficients of variation (5.3% in Amplicor; 2.6% in bDNA-2), and good linearity (r2 > or = 0.98). There was a positive correlation between quantification values of both methods (r = 0.683, p < 0.001). The Amplicor values were on an average 1.76 log lower than bDNA-2 results. Male subjects and HCV genotype 1b were significantly associated with higher viral load determined by Amplicor, but not with viral load measured by bDNA-2. In 70 chronic HCV infected patients treated with interferon alfa, mean (SD) pretreatment viral load in 27 complete responders (3.47 (0.84) logs for Amplicor, 5.63 (0.58) for bDNA-2) was significantly lower than in non-responders (4.43 (1.01) logs for Amplicor, 6.10 (0.67) logs for bDNA-2; p < 0.001). Cut off points of 3.9 logs for Amplicor and 5.8 logs for bDNA-2 were determined to be the best for predicting response to interferon alfa, giving acceptable sensitivity (70.4%, 74.1%), specificity (72.1%, 65.1%), and accuracy (71.4%, 68.6%), respectively. CONCLUSIONS: Both the Amplicor and bDNA-2 assays are clinically useful methods for HCV RNA quantification and are reliable for predicting the outcome of treatment, despite differences in absolute quantification values and in the correlation between HCV genotypes and viral load.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

AIM: To compare the performance characteristics and clinical application of two different technologies for quantifying serum hepatitis C virus (HCV) RNA levels. METHODS: HCV RNA was quantified by Amplicor HCV Monitor assay (Amplicor) and Quantiplex HCV RNA 2.0 assay (bDNA-2) in 119 sera from 107 HCV infected patients. RESULTS: Both assays had similar sensitivity (79.4% for Amplicor; 86.0% for bDNA-2), acceptable coefficients of variation (5.3% in Amplicor; 2.6% in bDNA-2), and good linearity (r2 > or = 0.98). There was a positive correlation between quantification values of both methods (r = 0.683, p < 0.001). The Amplicor values were on an average 1.76 log lower than bDNA-2 results. Male subjects and HCV genotype 1b were significantly associated with higher viral load determined by Amplicor, but not with viral load measured by bDNA-2. In 70 chronic HCV infected patients treated with interferon alfa, mean (SD) pretreatment viral load in 27 complete responders (3.47 (0.84) logs for Amplicor, 5.63 (0.58) for bDNA-2) was significantly lower than in non-responders (4.43 (1.01) logs for Amplicor, 6.10 (0.67) logs for bDNA-2; p < 0.001). Cut off points of 3.9 logs for Amplicor and 5.8 logs for bDNA-2 were determined to be the best for predicting response to interferon alfa, giving acceptable sensitivity (70.4%, 74.1%), specificity (72.1%, 65.1%), and accuracy (71.4%, 68.6%), respectively. CONCLUSIONS: Both the Amplicor and bDNA-2 assays are clinically useful methods for HCV RNA quantification and are reliable for predicting the outcome of treatment, despite differences in absolute quantification values and in the correlation between HCV genotypes and viral load.

Key concepts: BDNA test, Hepatitis C virus, Viral load, Virology, Hepacivirus, Interferon, Chronic hepatitis, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Clinical application of the Quantiplex HCV RNA 2.0 and Amplicor HCV Monitor assays for quantifying serum hepatitis C virus RNA. — Research Paper | ScholarLens