2005Journal of the Brazilian Chemical SocietyOpen access

An enzymatic flow-injection procedure with chemiluminescence detection for on-site determination of L-alanine in synthesis process

Eduardo Puentes Borges, Boaventura Freire dos Reis

Open full text 2 citations

Abstract

In this work an automatic flow procedure for L-alanine determination in the synthesis medium without a prior sample treatment is described. The method was based on oxidation of L-alanine by L-amino acid oxidize followed by the reaction of the H2O2 with luminol and chemiluminescence detection. In order to overcome the severe alkaline condition of the synthesis medium, a zone sampling strategy was employed for automatic sample dilution and pH adjustment. The procedure allows L-alanine determination in the range of 0.5 to 25.0 mmol L-1, a limit of detection of 0.08 mmol L-1 and a variation coefficient lower than 4% (n = 10). Other advantageous feature such as a sampling throughput of 44 determination per hour and low reagent consumption, 0.2 mg luminol and 16.4 mg hexacinoferrate(III) per determination, respectively, were also achieved.

Open-access reader

About this research paper

What this paper is about

In this work an automatic flow procedure for L-alanine determination in the synthesis medium without a prior sample treatment is described. The method was based on oxidation of L-alanine by L-amino acid oxidize followed by the reaction of the H2O2 with luminol and chemiluminescence detection. In order to overcome the severe alkaline condition of the synthesis medium, a zone sampling strategy was employed for automatic sample dilution and pH adjustment. The procedure allows L-alanine determination in the range of 0.5 to 25.0 mmol L-1, a limit of detection of 0.08 mmol L-1 and a variation coefficient lower than 4% (n = 10). Other advantageous feature such as a sampling throughput of 44 determination per hour and low reagent consumption, 0.2 mg luminol and 16.4 mg hexacinoferrate(III) per determination, respectively, were also achieved.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this work an automatic flow procedure for L-alanine determination in the synthesis medium without a prior sample treatment is described. The method was based on oxidation of L-alanine by L-amino acid oxidize followed by the reaction of the H2O2 with luminol and chemiluminescence detection. In order to overcome the severe alkaline condition of the synthesis medium, a zone sampling strategy was employed for automatic sample dilution and pH adjustment. The procedure allows L-alanine determination in the range of 0.5 to 25.0 mmol L-1, a limit of detection of 0.08 mmol L-1 and a variation coefficient lower than 4% (n = 10). Other advantageous feature such as a sampling throughput of 44 determination per hour and low reagent consumption, 0.2 mg luminol and 16.4 mg hexacinoferrate(III) per determination, respectively, were also achieved.

Key concepts: Chemiluminescence, Luminol, Detection limit, Reagent, Chemistry, Alanine, Chromatography, Flow injection analysis

Related papers

Back to paper searchBrowse research topicsOriginal source
An enzymatic flow-injection procedure with chemiluminescence detection for on-site determination of L-alanine in synthesis process — Research Paper | ScholarLens