1996Pacing and Clinical ElectrophysiologyRequires access

Atrial Flutter Mapping and Ablation II. Radiofrequency Ablation of Atrial Flutter Circuits

S. Serge Barol, Francisco G. Cosío, Fernando Arribas, María López‐Gil, H. DANIEL GONZÁLEZ

Open publisher page 48 citations

Abstract

The definition of the anatomical substrate of reentry in atrial flutter has allowed the recognition of narrow, critical areas of the circuit, where radiofrequency ablation can interrupt reentry. In common flutter the isthmus between the inferior vena cava and the tricuspid valve appears the best target, but ablation between the coronary sinus and tricuspid valve can also be effective in some cases. In atypical flutter using the same circuit as common flutter in a "clockwise" direction, ablation of the same isthmus is effective. Flutter interruption is the main objective, but it does not mean complete isthmus ablation. If flutter remains inducible, new applications are delivered in the isthmus, until it is made noninducible. Complications are rare. Despite attaining noninducibility, flutter may recur, and new procedures may be needed to prevent recurrence. Atrial fibrillation can occur in up to 30% of the cases during follow-up, but it is generally well controlled with antiarrhythmic drugs, that were ineffective to treat flutter before ablation. In reentry circuits based on surgical atrial scars, ablation of an isthmus between the scar and the inferior vena cava can also be effective. Left atrial circuits are not known well enough to guide successful ablation.

About this research paper

What this paper is about

The definition of the anatomical substrate of reentry in atrial flutter has allowed the recognition of narrow, critical areas of the circuit, where radiofrequency ablation can interrupt reentry. In common flutter the isthmus between the inferior vena cava and the tricuspid valve appears the best target, but ablation between the coronary sinus and tricuspid valve can also be effective in some cases. In atypical flutter using the same circuit as common flutter in a "clockwise" direction, ablation of the same isthmus is effective. Flutter interruption is the main objective, but it does not mean complete isthmus ablation. If flutter remains inducible, new applications are delivered in the isthmus, until it is made noninducible. Complications are rare. Despite attaining noninducibility, flutter may recur, and new procedures may be needed to prevent recurrence. Atrial fibrillation can occur in up to 30% of the cases during follow-up, but it is generally well controlled with antiarrhythmic drugs, that were ineffective to treat flutter before ablation. In reentry circuits based on surgical atrial scars, ablation of an isthmus between the scar and the inferior vena cava can also be effective. Left atrial circuits are not known well enough to guide successful ablation.

Why it matters

OpenAlex reports 48 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The definition of the anatomical substrate of reentry in atrial flutter has allowed the recognition of narrow, critical areas of the circuit, where radiofrequency ablation can interrupt reentry. In common flutter the isthmus between the inferior vena cava and the tricuspid valve appears the best target, but ablation between the coronary sinus and tricuspid valve can also be effective in some cases. In atypical flutter using the same circuit as common flutter in a "clockwise" direction, ablation of the same isthmus is effective. Flutter interruption is the main objective, but it does not mean complete isthmus ablation. If flutter remains inducible, new applications are delivered in the isthmus, until it is made noninducible. Complications are rare. Despite attaining noninducibility, flutter may recur, and new procedures may be needed to prevent recurrence. Atrial fibrillation can occur in up to 30% of the cases during follow-up, but it is generally well controlled with antiarrhythmic drugs, that were ineffective to treat flutter before ablation. In reentry circuits based on surgical atrial scars, ablation of an isthmus between the scar and the inferior vena cava can also be effective. Left atrial circuits are not known well enough to guide successful ablation.

Key concepts: Atrial flutter, Medicine, Ablation, Flutter, Reentry, Cardiology, Coronary sinus, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Atrial Flutter Mapping and Ablation II. Radiofrequency Ablation of Atrial Flutter Circuits — Research Paper | ScholarLens