1994The Journal of the Acoustical Society of AmericaRequires access

Changes in voice-onset time in speakers with cochlear implants

Harlan Lane, Jane Wozniak, Joseph S. Perkell

Open publisher page 27 citations

Abstract

Voice-onset time (VOT) and syllable duration were measured for the English plosives in /Cad/(C = consonant) context spoken by four postlingually deafened recipients of multichannel (Ineraid) cochlear implants. Recordings were made of their speech before, and at intervals following, activation of the speech processors of their implants. Three patients reduced mean syllable duration following activation. Using measures of VOT and syllable duration from speakers with normal hearing [Volaitis and Miller, J. Acoust. Soc. Am. 92, 723-735 (1992)] and from the subjects of this study, VOT is shown to vary approximately linearly with syllable duration over the ranges produced here. Therefore, the VOT of each token was adjusted for the change in syllable duration of that token relative to the mean syllable duration in the first baseline session. This variable, labeled VOTc, was used to evaluate the effects on voicing of the speakers' renewed access to the voicing contrast provided by their implants. Preimplant, all four speakers characteristically uttered voiced plosives with too-short VOT, compared to the measures for hearing speakers. Voiceless plosive mean VOT was also abnormally short for two of the speakers, and close to normal for the remaining two. With some hearing restored, subjects made relatively few errors with respect to voicing when identifying plosives in listening tests, and three of the four speakers lengthened VOTc. The findings are interpreted as supporting the hypothesis that speakers use their hearing to calibrate mechanisms of speech production by monitoring the relations between their articulations and their acoustic output.

About this research paper

What this paper is about

Voice-onset time (VOT) and syllable duration were measured for the English plosives in /Cad/(C = consonant) context spoken by four postlingually deafened recipients of multichannel (Ineraid) cochlear implants. Recordings were made of their speech before, and at intervals following, activation of the speech processors of their implants. Three patients reduced mean syllable duration following activation. Using measures of VOT and syllable duration from speakers with normal hearing [Volaitis and Miller, J. Acoust. Soc. Am. 92, 723-735 (1992)] and from the subjects of this study, VOT is shown to vary approximately linearly with syllable duration over the ranges produced here. Therefore, the VOT of each token was adjusted for the change in syllable duration of that token relative to the mean syllable duration in the first baseline session. This variable, labeled VOTc, was used to evaluate the effects on voicing of the speakers' renewed access to the voicing contrast provided by their implants. Preimplant, all four speakers characteristically uttered voiced plosives with too-short VOT, compared to the measures for hearing speakers. Voiceless plosive mean VOT was also abnormally short for two of the speakers, and close to normal for the remaining two. With some hearing restored, subjects made relatively few errors with respect to voicing when identifying plosives in listening tests, and three of the four speakers lengthened VOTc. The findings are interpreted as supporting the hypothesis that speakers use their hearing to calibrate mechanisms of speech production by monitoring the relations between their articulations and their acoustic output.

Why it matters

OpenAlex reports 27 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Voice-onset time (VOT) and syllable duration were measured for the English plosives in /Cad/(C = consonant) context spoken by four postlingually deafened recipients of multichannel (Ineraid) cochlear implants. Recordings were made of their speech before, and at intervals following, activation of the speech processors of their implants. Three patients reduced mean syllable duration following activation. Using measures of VOT and syllable duration from speakers with normal hearing [Volaitis and Miller, J. Acoust. Soc. Am. 92, 723-735 (1992)] and from the subjects of this study, VOT is shown to vary approximately linearly with syllable duration over the ranges produced here. Therefore, the VOT of each token was adjusted for the change in syllable duration of that token relative to the mean syllable duration in the first baseline session. This variable, labeled VOTc, was used to evaluate the effects on voicing of the speakers' renewed access to the voicing contrast provided by their implants. Preimplant, all four speakers characteristically uttered voiced plosives with too-short VOT, compared to the measures for hearing speakers. Voiceless plosive mean VOT was also abnormally short for two of the speakers, and close to normal for the remaining two. With some hearing restored, subjects made relatively few errors with respect to voicing when identifying plosives in listening tests, and three of the four speakers lengthened VOTc. The findings are interpreted as supporting the hypothesis that speakers use their hearing to calibrate mechanisms of speech production by monitoring the relations between their articulations and their acoustic output.

Key concepts: Audiology, Acoustics, Cochlear implant, Medicine, Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Changes in voice-onset time in speakers with cochlear implants — Research Paper | ScholarLens