Extraction and on-fiber derivatization of chlorophenols in leather by internally cooled solid phase microextraction
Cristine Durante de Souza Silveira, Josias de Oliveira Merib, Edmar Martendal, Eduardo Carasek
Abstract
Open-access reader
Cristine Durante de Souza Silveira, Josias de Oliveira Merib, Edmar Martendal, Eduardo Carasek
Abstract
Open-access reader
This study proposes a new analytical procedure based on an internally cooled solid phase microextraction technique (CF-SPME) combined with on-fiber derivatization and gas chromatography-selected ion monitoring-mass spectrometry (GC-SIM-MS) for the determination of phenols extracted directly from leather samples. The extraction and derivatization conditions were optimized using experimental designs, such as: extraction time and sample temperature of 5 min and 170 ºC, fiber recoat temperature of 20 ºC, and exposing the fiber to the headspace of 70 µL of bis(trimethylsylyl)trifluoro-acetamide derivatizing agent for 23 min. Detection limits ranging from 1.03 to 2.68 µg g-1 and relative standard deviation (RSD) lower than 15% (n = 5) were obtained. The recovery was studied at three concentration levels and excellent recoveries ranging from 64.5 to 92.3% were obtained.
OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
This study proposes a new analytical procedure based on an internally cooled solid phase microextraction technique (CF-SPME) combined with on-fiber derivatization and gas chromatography-selected ion monitoring-mass spectrometry (GC-SIM-MS) for the determination of phenols extracted directly from leather samples. The extraction and derivatization conditions were optimized using experimental designs, such as: extraction time and sample temperature of 5 min and 170 ºC, fiber recoat temperature of 20 ºC, and exposing the fiber to the headspace of 70 µL of bis(trimethylsylyl)trifluoro-acetamide derivatizing agent for 23 min. Detection limits ranging from 1.03 to 2.68 µg g-1 and relative standard deviation (RSD) lower than 15% (n = 5) were obtained. The recovery was studied at three concentration levels and excellent recoveries ranging from 64.5 to 92.3% were obtained.
Key concepts: Derivatization, Chromatography, Solid-phase microextraction, Extraction (chemistry), Mass spectrometry, Fiber, Gas chromatography–mass spectrometry, Chemistry