2004•Journal of the Brazilian Chemical SocietyOpen access

Determination of cadmium by flame-atomic absorption spectrometry after preconcentration on silica gel modified with cupferron

Gisele Gonçalves Bortoleto, Greice Trevisan Macarovscha, Solange Cadore

Open full text 43 citations

Abstract

A method for the determination of cadmium by flame atomic absorption spectrometry (FAAS) after its preconcentration onto a column containing silica gel modified with cupferron was developed. The pH, amount of adsorbent material, concentration of eluent, volume of sample and amount of Cd were optimized. The effect of several foreign ions was also investigated and showed that the retention of cadmium depended on the amounts of Zn(II) and Cu(II) present and that these interferences could be overcome by using a 0.05 mmol KI. An enrichment factor of up to 30 was obtained , the LOD was 0.5 µg L-1 (3sigma) and the LOQ was 2.0 µg L-1 (10sigma) with rsd of 1.1% (n = 10). The accuracy of the proposed method was ascertained by using certified reference material and the obtained result (3.93 ± 0.01 µg g-1) agrees with the certified value (4.15 ± 0.38 µg g-1). The determination of Cd in nail polish showed quantitative recoveries for the spiked samples. The proposed method is characterized by simplicity, efficiency and low cost.

Open-access reader

About this research paper

What this paper is about

A method for the determination of cadmium by flame atomic absorption spectrometry (FAAS) after its preconcentration onto a column containing silica gel modified with cupferron was developed. The pH, amount of adsorbent material, concentration of eluent, volume of sample and amount of Cd were optimized. The effect of several foreign ions was also investigated and showed that the retention of cadmium depended on the amounts of Zn(II) and Cu(II) present and that these interferences could be overcome by using a 0.05 mmol KI. An enrichment factor of up to 30 was obtained , the LOD was 0.5 µg L-1 (3sigma) and the LOQ was 2.0 µg L-1 (10sigma) with rsd of 1.1% (n = 10). The accuracy of the proposed method was ascertained by using certified reference material and the obtained result (3.93 ± 0.01 µg g-1) agrees with the certified value (4.15 ± 0.38 µg g-1). The determination of Cd in nail polish showed quantitative recoveries for the spiked samples. The proposed method is characterized by simplicity, efficiency and low cost.

Why it matters

OpenAlex reports 43 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for the determination of cadmium by flame atomic absorption spectrometry (FAAS) after its preconcentration onto a column containing silica gel modified with cupferron was developed. The pH, amount of adsorbent material, concentration of eluent, volume of sample and amount of Cd were optimized. The effect of several foreign ions was also investigated and showed that the retention of cadmium depended on the amounts of Zn(II) and Cu(II) present and that these interferences could be overcome by using a 0.05 mmol KI. An enrichment factor of up to 30 was obtained , the LOD was 0.5 µg L-1 (3sigma) and the LOQ was 2.0 µg L-1 (10sigma) with rsd of 1.1% (n = 10). The accuracy of the proposed method was ascertained by using certified reference material and the obtained result (3.93 ± 0.01 µg g-1) agrees with the certified value (4.15 ± 0.38 µg g-1). The determination of Cd in nail polish showed quantitative recoveries for the spiked samples. The proposed method is characterized by simplicity, efficiency and low cost.

Key concepts: Chemistry, Cadmium, Certified reference materials, Adsorption, Atomic absorption spectroscopy, Silica gel, Chromatography, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of cadmium by flame-atomic absorption spectrometry after preconcentration on silica gel modified with cupferron — Research Paper | ScholarLens