1997Magnetic Resonance in MedicineRequires access

On the SAR and field inhomogeneity of birdcage coils loaded with the human head

Jian‐Ming Jin, Ji Chen

Open publisher page 92 citations

Abstract

Birdcage coils are widely used as a radiofrequency (RF) resonator in magnetic resonance imaging (MRI) because of their capability to produce a highly homogeneous B1 field over a large volume within the coil. When they are employed for high-frequency MRI, the interaction between the electromagnetic field and the object to be imaged deteriorates the B1-field homogeneity and increases the specific absorption rate (SAR) in the object. To investigate this problem, a finite-element method (FEM) is developed to analyze the SAR and the B1 field in a two-dimensional (2D) model of a birdcage coil loaded with a 2D model of a human head. The electric field, magnetic field, and SAR distributions are shown, and a comprehensive study is carried out for both linear and quadrature birdcage coils at 64, 128, 171, and 256 MHz. It is shown that to generate the same value of the B1 field, the SAR is increased significantly with the frequency, and for the same imaging method the SAR produced by a quadrature coil is significantly lower than that of a linear coil. It is also shown that the B1-field inhomogeneity is increased significantly with the frequency.

About this research paper

What this paper is about

Birdcage coils are widely used as a radiofrequency (RF) resonator in magnetic resonance imaging (MRI) because of their capability to produce a highly homogeneous B1 field over a large volume within the coil. When they are employed for high-frequency MRI, the interaction between the electromagnetic field and the object to be imaged deteriorates the B1-field homogeneity and increases the specific absorption rate (SAR) in the object. To investigate this problem, a finite-element method (FEM) is developed to analyze the SAR and the B1 field in a two-dimensional (2D) model of a birdcage coil loaded with a 2D model of a human head. The electric field, magnetic field, and SAR distributions are shown, and a comprehensive study is carried out for both linear and quadrature birdcage coils at 64, 128, 171, and 256 MHz. It is shown that to generate the same value of the B1 field, the SAR is increased significantly with the frequency, and for the same imaging method the SAR produced by a quadrature coil is significantly lower than that of a linear coil. It is also shown that the B1-field inhomogeneity is increased significantly with the frequency.

Why it matters

OpenAlex reports 92 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Birdcage coils are widely used as a radiofrequency (RF) resonator in magnetic resonance imaging (MRI) because of their capability to produce a highly homogeneous B1 field over a large volume within the coil. When they are employed for high-frequency MRI, the interaction between the electromagnetic field and the object to be imaged deteriorates the B1-field homogeneity and increases the specific absorption rate (SAR) in the object. To investigate this problem, a finite-element method (FEM) is developed to analyze the SAR and the B1 field in a two-dimensional (2D) model of a birdcage coil loaded with a 2D model of a human head. The electric field, magnetic field, and SAR distributions are shown, and a comprehensive study is carried out for both linear and quadrature birdcage coils at 64, 128, 171, and 256 MHz. It is shown that to generate the same value of the B1 field, the SAR is increased significantly with the frequency, and for the same imaging method the SAR produced by a quadrature coil is significantly lower than that of a linear coil. It is also shown that the B1-field inhomogeneity is increased significantly with the frequency.

Key concepts: Electromagnetic coil, Specific absorption rate, Human head, Radiofrequency coil, Nuclear magnetic resonance, Physics, Resonator, Magnetic field

Related papers

Back to paper searchBrowse research topicsOriginal source
On the SAR and field inhomogeneity of birdcage coils loaded with the human head — Research Paper | ScholarLens