2005Unpublished venueRequires access

Multiple probe hepatic radio-frequency ablation: ex-vivo experiments in the porcine model

Dieter Haemmerich, John G. Webster, F.T. Lee, Arianna Wright, David M. Mahvi

Open publisher page 1 citations

Abstract

Radio-frequency (RF) ablation is an important means of treatment of non-resectable primary and metastatic liver tumors. The RF ablation of any but the smallest tumor requires the use of multiple overlapping treatment zones. Commercially available RF ablation generators, unlike cryoablation (a method of tumor destruction that utilizes cold rather than heat), are only capable of driving a single RF probe at a time. Using multiple probes simultaneously in RF ablation is desirable for treating large tumors and for treating multiple tumor metastases. Bipolar RF ablation, which has been previously studied by other groups, allows simultaneous usage of two probes. The energy converted to heat at each probe for bipolar RF ablation is necessarily equal. There have been no investigations of other methods that allow usage of multiple RF probes simultaneously. We investigated the feasibility of a new method, where power is applied in an alternating fashion between two or more probes. This method allows independent control of the amount of energy deposited at each probe. We performed ex-vivo experiments with one (i.e. conventional ablation) and with two probes. In the two-probe experiment, both probes reached target temperature and created lesions of sizes comparable to conventional RF ablation.

About this research paper

What this paper is about

Radio-frequency (RF) ablation is an important means of treatment of non-resectable primary and metastatic liver tumors. The RF ablation of any but the smallest tumor requires the use of multiple overlapping treatment zones. Commercially available RF ablation generators, unlike cryoablation (a method of tumor destruction that utilizes cold rather than heat), are only capable of driving a single RF probe at a time. Using multiple probes simultaneously in RF ablation is desirable for treating large tumors and for treating multiple tumor metastases. Bipolar RF ablation, which has been previously studied by other groups, allows simultaneous usage of two probes. The energy converted to heat at each probe for bipolar RF ablation is necessarily equal. There have been no investigations of other methods that allow usage of multiple RF probes simultaneously. We investigated the feasibility of a new method, where power is applied in an alternating fashion between two or more probes. This method allows independent control of the amount of energy deposited at each probe. We performed ex-vivo experiments with one (i.e. conventional ablation) and with two probes. In the two-probe experiment, both probes reached target temperature and created lesions of sizes comparable to conventional RF ablation.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Radio-frequency (RF) ablation is an important means of treatment of non-resectable primary and metastatic liver tumors. The RF ablation of any but the smallest tumor requires the use of multiple overlapping treatment zones. Commercially available RF ablation generators, unlike cryoablation (a method of tumor destruction that utilizes cold rather than heat), are only capable of driving a single RF probe at a time. Using multiple probes simultaneously in RF ablation is desirable for treating large tumors and for treating multiple tumor metastases. Bipolar RF ablation, which has been previously studied by other groups, allows simultaneous usage of two probes. The energy converted to heat at each probe for bipolar RF ablation is necessarily equal. There have been no investigations of other methods that allow usage of multiple RF probes simultaneously. We investigated the feasibility of a new method, where power is applied in an alternating fashion between two or more probes. This method allows independent control of the amount of energy deposited at each probe. We performed ex-vivo experiments with one (i.e. conventional ablation) and with two probes. In the two-probe experiment, both probes reached target temperature and created lesions of sizes comparable to conventional RF ablation.

Key concepts: Ablation, Radio frequency, Rf ablation, Cryoablation, RF probe, Materials science, Ex vivo, Radiofrequency ablation

Related papers

Back to paper searchBrowse research topicsOriginal source
Multiple probe hepatic radio-frequency ablation: ex-vivo experiments in the porcine model — Research Paper | ScholarLens