BACKGROUND: Topical anesthetic agents are widely used to mitigate the pain associated with laser and high-energy pulsed light source hair removal. OBJECTIVE: To evaluate the relative efficacy and onset of action of a new topical anesthetic agent, ELA-Max cream (lidocaine 4%), relative to a widely used agent, EMLA cream (lidocaine 2.5%/prilocaine 2.5%). METHODS: ELA-Max and EMLA were applied to the forearms of 10 unblinded test subjects. The EMLA-treated sites were occluded for 1.5 hours prior to testing. The ELA-Max-treated sites were unoccluded and the cream was applied immediately prior to testing. Pulses from an Epilight high-energy pulsed light source were then administered 1.5 hours after occlusion with EMLA and in 5-minute intervals after application of ELA-Max. Pain scores were recorded on a visual analog scale (VAS). RESULTS: Six of 10 patients reported some anesthetic effect from ELA-Max after 5 minutes of unoccluded skin contact. Seven of 10 subjects reported maximal pain control 20 minutes after application of unoccluded ELA-Max, roughly equivalent to EMLA after 1.5 hours of occlusion. CONCLUSION: ELA-Max is an effective topical anesthetic agent comparable to EMLA under occlusion. It appears to be faster acting than EMLA, and along with its effectiveness without occlusion, may be an easier agent to use.

About this research paper

What this paper is about

BACKGROUND: Topical anesthetic agents are widely used to mitigate the pain associated with laser and high-energy pulsed light source hair removal. OBJECTIVE: To evaluate the relative efficacy and onset of action of a new topical anesthetic agent, ELA-Max cream (lidocaine 4%), relative to a widely used agent, EMLA cream (lidocaine 2.5%/prilocaine 2.5%). METHODS: ELA-Max and EMLA were applied to the forearms of 10 unblinded test subjects. The EMLA-treated sites were occluded for 1.5 hours prior to testing. The ELA-Max-treated sites were unoccluded and the cream was applied immediately prior to testing. Pulses from an Epilight high-energy pulsed light source were then administered 1.5 hours after occlusion with EMLA and in 5-minute intervals after application of ELA-Max. Pain scores were recorded on a visual analog scale (VAS). RESULTS: Six of 10 patients reported some anesthetic effect from ELA-Max after 5 minutes of unoccluded skin contact. Seven of 10 subjects reported maximal pain control 20 minutes after application of unoccluded ELA-Max, roughly equivalent to EMLA after 1.5 hours of occlusion. CONCLUSION: ELA-Max is an effective topical anesthetic agent comparable to EMLA under occlusion. It appears to be faster acting than EMLA, and along with its effectiveness without occlusion, may be an easier agent to use.

Why it matters

OpenAlex reports 27 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Topical anesthetic agents are widely used to mitigate the pain associated with laser and high-energy pulsed light source hair removal. OBJECTIVE: To evaluate the relative efficacy and onset of action of a new topical anesthetic agent, ELA-Max cream (lidocaine 4%), relative to a widely used agent, EMLA cream (lidocaine 2.5%/prilocaine 2.5%). METHODS: ELA-Max and EMLA were applied to the forearms of 10 unblinded test subjects. The EMLA-treated sites were occluded for 1.5 hours prior to testing. The ELA-Max-treated sites were unoccluded and the cream was applied immediately prior to testing. Pulses from an Epilight high-energy pulsed light source were then administered 1.5 hours after occlusion with EMLA and in 5-minute intervals after application of ELA-Max. Pain scores were recorded on a visual analog scale (VAS). RESULTS: Six of 10 patients reported some anesthetic effect from ELA-Max after 5 minutes of unoccluded skin contact. Seven of 10 subjects reported maximal pain control 20 minutes after application of unoccluded ELA-Max, roughly equivalent to EMLA after 1.5 hours of occlusion. CONCLUSION: ELA-Max is an effective topical anesthetic agent comparable to EMLA under occlusion. It appears to be faster acting than EMLA, and along with its effectiveness without occlusion, may be an easier agent to use.

Key concepts: Lidocaine, Medicine, Topical anesthetic, Prilocaine, Local anesthetic, Anesthesia, Anesthetic, Anesthetic Agent

Related papers

Back to paper searchBrowse research topicsOriginal source
High-Energy Pulsed Light Source Hair Removal Device Used to Evaluate the Onset of Action of a New Topical Anesthetic — Research Paper | ScholarLens