EXPERIMENTAL STUDY OF VOLUME CALIBRATION OF MASS WEIGHT WITH HYDROSTATIC WEIGHING
HONG MAN HU, Jian Wang, Yue Zhang, Chang Cai, Rui Zhong, Hong Yao, Jing Ding
Abstract
Open-access reader
HONG MAN HU, Jian Wang, Yue Zhang, Chang Cai, Rui Zhong, Hong Yao, Jing Ding
Abstract
Open-access reader
In this paper, the volumes of mass weights ranging from 500 g to 1 g are calibrated with a fused quartz solid density standard using a hydrostatic weighing device developed by Lab of Volume and Density in NIM, China. The stability of liquid temperature is discussed. And also the measurement uncertainty of the densities is evaluated based on the calibration models.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
In this paper, the volumes of mass weights ranging from 500 g to 1 g are calibrated with a fused quartz solid density standard using a hydrostatic weighing device developed by Lab of Volume and Density in NIM, China. The stability of liquid temperature is discussed. And also the measurement uncertainty of the densities is evaluated based on the calibration models.
Key concepts: Hydrostatic weighing, Calibration, Hydrostatic equilibrium, Volume (thermodynamics), Hydrostatic pressure, Quartz, Ranging, Materials science