Analysis of Normal and Infected Bio-Cell Using Dual Nanoprobe

Akter Hossain, Mohammad Shafkat Islam, Hedayet Ullah

Open publisher page 0 citations

Abstract

The objective of this paper is to analyze the yeast cell, liver cell and blood cell under both infected and healthy conditions by applying electrical signal through dual nanoprobe from source to cell. Knowledge of nanoprobe based bio-cell analysis can be used to differentiate infected cells from healthy ones, since their electrical behaviour is different. The voltage can be applied either inside the cytoplasm penetrating the cell wall, or at the outer surface of cell membrane. In this paper, the simulation has been carried out by applying voltage inside the cytoplasm using ABAQUS 6.10 CAE, powerful finite element software and the results obtained from simulation shows current flow healthy yeast and dead yeast cells are 1·9nA and 34pA respectively whereas the value of the current measured for the leukaemia affected blood cell is 21·2nA, being 2% less than the White Blood Cell (WBC). Since the conductivity of the cytoplasm of the healthy cell is theoretically higher than that of dead or infected cell, which is verified by simulation. The results from simulation show that the measured cell current from liver tumour cell is 2-7 times larger than healthy liver cell including membrane as it is supposed to be since the conductivity of cell including cell membrane is theoretically greater for dead or infected cell than healthy cell.

About this research paper

What this paper is about

The objective of this paper is to analyze the yeast cell, liver cell and blood cell under both infected and healthy conditions by applying electrical signal through dual nanoprobe from source to cell. Knowledge of nanoprobe based bio-cell analysis can be used to differentiate infected cells from healthy ones, since their electrical behaviour is different. The voltage can be applied either inside the cytoplasm penetrating the cell wall, or at the outer surface of cell membrane. In this paper, the simulation has been carried out by applying voltage inside the cytoplasm using ABAQUS 6.10 CAE, powerful finite element software and the results obtained from simulation shows current flow healthy yeast and dead yeast cells are 1·9nA and 34pA respectively whereas the value of the current measured for the leukaemia affected blood cell is 21·2nA, being 2% less than the White Blood Cell (WBC). Since the conductivity of the cytoplasm of the healthy cell is theoretically higher than that of dead or infected cell, which is verified by simulation. The results from simulation show that the measured cell current from liver tumour cell is 2-7 times larger than healthy liver cell including membrane as it is supposed to be since the conductivity of cell including cell membrane is theoretically greater for dead or infected cell than healthy cell.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The objective of this paper is to analyze the yeast cell, liver cell and blood cell under both infected and healthy conditions by applying electrical signal through dual nanoprobe from source to cell. Knowledge of nanoprobe based bio-cell analysis can be used to differentiate infected cells from healthy ones, since their electrical behaviour is different. The voltage can be applied either inside the cytoplasm penetrating the cell wall, or at the outer surface of cell membrane. In this paper, the simulation has been carried out by applying voltage inside the cytoplasm using ABAQUS 6.10 CAE, powerful finite element software and the results obtained from simulation shows current flow healthy yeast and dead yeast cells are 1·9nA and 34pA respectively whereas the value of the current measured for the leukaemia affected blood cell is 21·2nA, being 2% less than the White Blood Cell (WBC). Since the conductivity of the cytoplasm of the healthy cell is theoretically higher than that of dead or infected cell, which is verified by simulation. The results from simulation show that the measured cell current from liver tumour cell is 2-7 times larger than healthy liver cell including membrane as it is supposed to be since the conductivity of cell including cell membrane is theoretically greater for dead or infected cell than healthy cell.

Key concepts: Cytoplasm, Nanoprobe, Cell, Yeast, Cell membrane, Liver cell, Membrane, Cell biology