2009IEEE Sensors JournalRequires access

Dual-Mode Capacitive Proximity Sensor for Robot Application: Implementation of Tactile and Proximity Sensing Capability on a Single Polymer Platform Using Shared Electrodes

Hyung-Kew Lee, Sun-Il Chang, Euisik Yoon

Open publisher page 210 citations

Abstract

In this paper, we report a flexible dual-mode capacitive sensor for robot applications which has two sensing capabilities in a single platform; tactile and proximity sensing capability. The sensor consists of a mechanical structure based on PDMS (Polydimethylsiloxane) and a mesh of multiple copper electrode strips. The mesh is composed of 16 top and 16 bottom copper strips crossed each other to form a 16 times 16 capacitor array. The proposed sensor is able to switch its function from tactile sensing to proximity sensing or vice versa by reconfiguring the connection of electrodes. The tactile sensing capability has been demonstrated already and reported in our previous paper (Lee et al.,, 2006); therefore, in this paper, we will demonstrate the feasibility of the proximity sensing capability and the dual-mode operation of the proposed sensor in detail. The capacitance change caused by an approaching object has been estimated through simulation of multiple two-dimensional models as an initial study. The measured data have shown similar trends with the simulation results. We tested various materials from conducting metals to a human hand for proximity measurement. The fabricated sensor could detect a human hand at a distance up to 17 cm away from the sensor. We also have successfully demonstrated the feasibility of dual-mode operation of the proposed sensor in real-time exploiting a custom designed PCB, a data acquisition pad, and Labview software.

About this research paper

What this paper is about

In this paper, we report a flexible dual-mode capacitive sensor for robot applications which has two sensing capabilities in a single platform; tactile and proximity sensing capability. The sensor consists of a mechanical structure based on PDMS (Polydimethylsiloxane) and a mesh of multiple copper electrode strips. The mesh is composed of 16 top and 16 bottom copper strips crossed each other to form a 16 times 16 capacitor array. The proposed sensor is able to switch its function from tactile sensing to proximity sensing or vice versa by reconfiguring the connection of electrodes. The tactile sensing capability has been demonstrated already and reported in our previous paper (Lee et al.,, 2006); therefore, in this paper, we will demonstrate the feasibility of the proximity sensing capability and the dual-mode operation of the proposed sensor in detail. The capacitance change caused by an approaching object has been estimated through simulation of multiple two-dimensional models as an initial study. The measured data have shown similar trends with the simulation results. We tested various materials from conducting metals to a human hand for proximity measurement. The fabricated sensor could detect a human hand at a distance up to 17 cm away from the sensor. We also have successfully demonstrated the feasibility of dual-mode operation of the proposed sensor in real-time exploiting a custom designed PCB, a data acquisition pad, and Labview software.

Why it matters

OpenAlex reports 210 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this paper, we report a flexible dual-mode capacitive sensor for robot applications which has two sensing capabilities in a single platform; tactile and proximity sensing capability. The sensor consists of a mechanical structure based on PDMS (Polydimethylsiloxane) and a mesh of multiple copper electrode strips. The mesh is composed of 16 top and 16 bottom copper strips crossed each other to form a 16 times 16 capacitor array. The proposed sensor is able to switch its function from tactile sensing to proximity sensing or vice versa by reconfiguring the connection of electrodes. The tactile sensing capability has been demonstrated already and reported in our previous paper (Lee et al.,, 2006); therefore, in this paper, we will demonstrate the feasibility of the proximity sensing capability and the dual-mode operation of the proposed sensor in detail. The capacitance change caused by an approaching object has been estimated through simulation of multiple two-dimensional models as an initial study. The measured data have shown similar trends with the simulation results. We tested various materials from conducting metals to a human hand for proximity measurement. The fabricated sensor could detect a human hand at a distance up to 17 cm away from the sensor. We also have successfully demonstrated the feasibility of dual-mode operation of the proposed sensor in real-time exploiting a custom designed PCB, a data acquisition pad, and Labview software.

Key concepts: Tactile sensor, Capacitive sensing, Proximity sensor, Capacitance, Electrode, Polydimethylsiloxane, Robot, Capacitor

Related papers

Back to paper searchBrowse research topicsOriginal source
Dual-Mode Capacitive Proximity Sensor for Robot Application: Implementation of Tactile and Proximity Sensing Capability on a Single Polymer Platform Using Shared Electrodes — Research Paper | ScholarLens