1999RadiologyRequires access

Intracranial Aneurysms: Detection with Three-dimensional CT Angiography with Volume Rendering—Comparison with Conventional Angiographic and Surgical Findings

Yukunori Korogi, Mutsumasa Takahashi, Kazuhiro Katada, Yuko Ogura, Kanehiro Hasuo, Makoto Ochi, Hidetsuna Utsunomiya, Toshi Abe, Satoshi Imakita

Open publisher page 189 citations

Abstract

PURPOSE: To assess the diagnostic accuracy of three-dimensional (3D) computed tomographic (CT) angiography for intracranial aneurysms. MATERIALS AND METHODS: The 3D CT angiograms obtained in 49 patients with or without intracranial aneurysms were evaluated by four blinded observers. Results were compared with findings at conventional angiography or surgery. A volume-rendering method was used, and 13 images obtained in different directions were reviewed in each study. The diameter of aneurysms was divided into four sizes: large, greater than 13 mm; medium, 5-12 mm; small, 3-4 mm; and very small, less than 3 mm. Results were also evaluated by means of receiver operating characteristic analysis. RESULTS: At conventional angiography, 47 aneurysms, including 14 less than 3 mm, were depicted in 35 patients. The mean sensitivity of CT angiography for very small aneurysms was 64%; small, 83%; medium, 95%; and large, 100%. Some very small aneurysms that were not depicted at conventional angiography were depicted at CT angiography, and one was proved at surgery. CONCLUSION: CT angiography has good sensitivity for depiction of intracranial aneurysms 3 mm or larger and relatively good sensitivity for aneurysms less than 3 mm. CT angiography may be a noninvasive technique for detection of asymptomatic unruptured or ruptured aneurysms.

About this research paper

What this paper is about

PURPOSE: To assess the diagnostic accuracy of three-dimensional (3D) computed tomographic (CT) angiography for intracranial aneurysms. MATERIALS AND METHODS: The 3D CT angiograms obtained in 49 patients with or without intracranial aneurysms were evaluated by four blinded observers. Results were compared with findings at conventional angiography or surgery. A volume-rendering method was used, and 13 images obtained in different directions were reviewed in each study. The diameter of aneurysms was divided into four sizes: large, greater than 13 mm; medium, 5-12 mm; small, 3-4 mm; and very small, less than 3 mm. Results were also evaluated by means of receiver operating characteristic analysis. RESULTS: At conventional angiography, 47 aneurysms, including 14 less than 3 mm, were depicted in 35 patients. The mean sensitivity of CT angiography for very small aneurysms was 64%; small, 83%; medium, 95%; and large, 100%. Some very small aneurysms that were not depicted at conventional angiography were depicted at CT angiography, and one was proved at surgery. CONCLUSION: CT angiography has good sensitivity for depiction of intracranial aneurysms 3 mm or larger and relatively good sensitivity for aneurysms less than 3 mm. CT angiography may be a noninvasive technique for detection of asymptomatic unruptured or ruptured aneurysms.

Why it matters

OpenAlex reports 189 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To assess the diagnostic accuracy of three-dimensional (3D) computed tomographic (CT) angiography for intracranial aneurysms. MATERIALS AND METHODS: The 3D CT angiograms obtained in 49 patients with or without intracranial aneurysms were evaluated by four blinded observers. Results were compared with findings at conventional angiography or surgery. A volume-rendering method was used, and 13 images obtained in different directions were reviewed in each study. The diameter of aneurysms was divided into four sizes: large, greater than 13 mm; medium, 5-12 mm; small, 3-4 mm; and very small, less than 3 mm. Results were also evaluated by means of receiver operating characteristic analysis. RESULTS: At conventional angiography, 47 aneurysms, including 14 less than 3 mm, were depicted in 35 patients. The mean sensitivity of CT angiography for very small aneurysms was 64%; small, 83%; medium, 95%; and large, 100%. Some very small aneurysms that were not depicted at conventional angiography were depicted at CT angiography, and one was proved at surgery. CONCLUSION: CT angiography has good sensitivity for depiction of intracranial aneurysms 3 mm or larger and relatively good sensitivity for aneurysms less than 3 mm. CT angiography may be a noninvasive technique for detection of asymptomatic unruptured or ruptured aneurysms.

Key concepts: Medicine, Angiography, Radiology, Aneurysm, Asymptomatic, Computed tomographic angiography, Cerebral angiography, Receiver operating characteristic

Related papers

Back to paper searchBrowse research topicsOriginal source
Intracranial Aneurysms: Detection with Three-dimensional CT Angiography with Volume Rendering—Comparison with Conventional Angiographic and Surgical Findings — Research Paper | ScholarLens