2012Unpublished venueRequires access

Study on Optimal Design of a Box-Culvert under Road

Ping Zhu, Run Liu, Wenbin Liu, WU Xin-li

Open publisher page 4 citations

Abstract

In order to connect a reservoir to the water system of an inner lake in a planned residential district, as well as pass through an urban first-grade highway, a box-culvert structure will be built under the highway. The larger cross-section of the box-culvert in the preliminary design is on the conservatively safer side but not as economical, and yet will cause excessive foundation deformation due to heaver self-structural load. This paper proposed an optimal design with the best combinations of sidewalls, floor, and roof thickness of the box-culvert structure. Finite element method analysis of the stress and deformation of the box-culvert structure and its foundation with the highest and lowest water table levers during its simulated construction period was conducted. As a result, an optimal design was concluded, which not only reduces the use of concrete, but also reduces the demands on the bearing capacity of the foundation soil.

About this research paper

What this paper is about

In order to connect a reservoir to the water system of an inner lake in a planned residential district, as well as pass through an urban first-grade highway, a box-culvert structure will be built under the highway. The larger cross-section of the box-culvert in the preliminary design is on the conservatively safer side but not as economical, and yet will cause excessive foundation deformation due to heaver self-structural load. This paper proposed an optimal design with the best combinations of sidewalls, floor, and roof thickness of the box-culvert structure. Finite element method analysis of the stress and deformation of the box-culvert structure and its foundation with the highest and lowest water table levers during its simulated construction period was conducted. As a result, an optimal design was concluded, which not only reduces the use of concrete, but also reduces the demands on the bearing capacity of the foundation soil.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In order to connect a reservoir to the water system of an inner lake in a planned residential district, as well as pass through an urban first-grade highway, a box-culvert structure will be built under the highway. The larger cross-section of the box-culvert in the preliminary design is on the conservatively safer side but not as economical, and yet will cause excessive foundation deformation due to heaver self-structural load. This paper proposed an optimal design with the best combinations of sidewalls, floor, and roof thickness of the box-culvert structure. Finite element method analysis of the stress and deformation of the box-culvert structure and its foundation with the highest and lowest water table levers during its simulated construction period was conducted. As a result, an optimal design was concluded, which not only reduces the use of concrete, but also reduces the demands on the bearing capacity of the foundation soil.

Key concepts: Culvert, Foundation (evidence), Roof, Finite element method, Structural engineering, Deformation (meteorology), Geotechnical engineering, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source