1993•British Journal of RadiologyRequires access

Variation of linear accelerator wedge factors with field size and wedge position

S. Thomas, R L Thomas

Open publisher page 2 citations

Abstract

We refer to the letter by Dean and Davis (1991) in which the authors suggested that “no extensive wedge factor versus field size measurements need be done for linear accelerators designed with a wedge mounted below the movable collimators”. They reported measurements on a Varian 2100C linear accelerator showing very little variation of wedge factor with field size, and contrasted these measurements on a Philips SL75/14 (Palta et al, 1988) and on an ABB LA20 (Thomas, 1990), both of which exhibited large increases in wedge factor (WF) with increasing field size.

About this research paper

What this paper is about

We refer to the letter by Dean and Davis (1991) in which the authors suggested that “no extensive wedge factor versus field size measurements need be done for linear accelerators designed with a wedge mounted below the movable collimators”. They reported measurements on a Varian 2100C linear accelerator showing very little variation of wedge factor with field size, and contrasted these measurements on a Philips SL75/14 (Palta et al, 1988) and on an ABB LA20 (Thomas, 1990), both of which exhibited large increases in wedge factor (WF) with increasing field size.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We refer to the letter by Dean and Davis (1991) in which the authors suggested that “no extensive wedge factor versus field size measurements need be done for linear accelerators designed with a wedge mounted below the movable collimators”. They reported measurements on a Varian 2100C linear accelerator showing very little variation of wedge factor with field size, and contrasted these measurements on a Philips SL75/14 (Palta et al, 1988) and on an ABB LA20 (Thomas, 1990), both of which exhibited large increases in wedge factor (WF) with increasing field size.

Key concepts: Wedge (geometry), Linear particle accelerator, Field size, Physics, Optics, Beam (structure)

Related papers

Back to paper searchBrowse research topicsOriginal source
Variation of linear accelerator wedge factors with field size and wedge position — Research Paper | ScholarLens