Fault current contribution of DFIG under unsymmetrical fault

Zhengrong Wu, Gang Wang, Haifeng Li, TongLe Ding, Xiang Gao

Open publisher page 6 citations

Abstract

In this paper, the transient characteristics of double-fed induction generator (DFIG) are analyzed. Based on this, the fault current contribution of DFIG with and without crowbar are compared. Comparison result shows that fault current of DFIG under different ride-through conditions differs widely from each other. Under unsymmetrical fault, the DFIG with a crowbar is converted to squirrel case induction as a load connected to grid and the positive or negative sequence current is determined by each equivalent circuit. As to the DFIG without a crowbar, negative sequence current is determined by its equivalent circuit and the positive sequence current is adjusted by the excitation system with its output related to the control of DFIG. The methods for calculating fault current contribution of DFIG under these two ride-through conditions are also presented. Then, the negative effect on protection that caused by different DFIG is studied. At the end, a case is set up to verify the accuracy of methods for calculating fault current contribution. The simulation result also shows the difference of DFIG fault current under different ride-through conditions.

About this research paper

What this paper is about

In this paper, the transient characteristics of double-fed induction generator (DFIG) are analyzed. Based on this, the fault current contribution of DFIG with and without crowbar are compared. Comparison result shows that fault current of DFIG under different ride-through conditions differs widely from each other. Under unsymmetrical fault, the DFIG with a crowbar is converted to squirrel case induction as a load connected to grid and the positive or negative sequence current is determined by each equivalent circuit. As to the DFIG without a crowbar, negative sequence current is determined by its equivalent circuit and the positive sequence current is adjusted by the excitation system with its output related to the control of DFIG. The methods for calculating fault current contribution of DFIG under these two ride-through conditions are also presented. Then, the negative effect on protection that caused by different DFIG is studied. At the end, a case is set up to verify the accuracy of methods for calculating fault current contribution. The simulation result also shows the difference of DFIG fault current under different ride-through conditions.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this paper, the transient characteristics of double-fed induction generator (DFIG) are analyzed. Based on this, the fault current contribution of DFIG with and without crowbar are compared. Comparison result shows that fault current of DFIG under different ride-through conditions differs widely from each other. Under unsymmetrical fault, the DFIG with a crowbar is converted to squirrel case induction as a load connected to grid and the positive or negative sequence current is determined by each equivalent circuit. As to the DFIG without a crowbar, negative sequence current is determined by its equivalent circuit and the positive sequence current is adjusted by the excitation system with its output related to the control of DFIG. The methods for calculating fault current contribution of DFIG under these two ride-through conditions are also presented. Then, the negative effect on protection that caused by different DFIG is studied. At the end, a case is set up to verify the accuracy of methods for calculating fault current contribution. The simulation result also shows the difference of DFIG fault current under different ride-through conditions.

Key concepts: Crowbar, Doubly fed electric machine, Fault (geology), Control theory (sociology), Current (fluid), Induction generator, Generator (circuit theory), Computer science

Related papers

Back to paper searchBrowse research topicsOriginal source
Fault current contribution of DFIG under unsymmetrical fault — Research Paper | ScholarLens