A CMOS chopper-stabilized differential difference amplifier for biomedical integrated circuits

Pak Kwong CHAN, Kian Ann Ng, X.L. Zhang

Open publisher page 35 citations

Abstract

A new CMOS chopper-stabilized differential difference amplifier (CHSDDA) that exploits the combination of chopper technique with differential difference amplifier is proposed, with advantages for use in instrumentation circuits requiring floating differential input and single-ended output. When configured as an instrumentation amplifier (IA), it operates as the analog front-end (AFE) for an electroencephalogram (EEG) recording system in integrated biomedical systems. The measurement results have shown that it achieves 1/f noise reduction, CMRR more than 120 dB (0-700 Hz), dc offset less than 16.5 /spl mu/V and current drain of 150 /spl mu/A at a 3 V single supply using a standard 0.6 /spl mu/m CMOS technology.

About this research paper

What this paper is about

A new CMOS chopper-stabilized differential difference amplifier (CHSDDA) that exploits the combination of chopper technique with differential difference amplifier is proposed, with advantages for use in instrumentation circuits requiring floating differential input and single-ended output. When configured as an instrumentation amplifier (IA), it operates as the analog front-end (AFE) for an electroencephalogram (EEG) recording system in integrated biomedical systems. The measurement results have shown that it achieves 1/f noise reduction, CMRR more than 120 dB (0-700 Hz), dc offset less than 16.5 /spl mu/V and current drain of 150 /spl mu/A at a 3 V single supply using a standard 0.6 /spl mu/m CMOS technology.

Why it matters

OpenAlex reports 35 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new CMOS chopper-stabilized differential difference amplifier (CHSDDA) that exploits the combination of chopper technique with differential difference amplifier is proposed, with advantages for use in instrumentation circuits requiring floating differential input and single-ended output. When configured as an instrumentation amplifier (IA), it operates as the analog front-end (AFE) for an electroencephalogram (EEG) recording system in integrated biomedical systems. The measurement results have shown that it achieves 1/f noise reduction, CMRR more than 120 dB (0-700 Hz), dc offset less than 16.5 /spl mu/V and current drain of 150 /spl mu/A at a 3 V single supply using a standard 0.6 /spl mu/m CMOS technology.

Key concepts: Chopper, Instrumentation amplifier, CMOS, Differential amplifier, Amplifier, Input offset voltage, Operational amplifier, Electrical engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
A CMOS chopper-stabilized differential difference amplifier for biomedical integrated circuits — Research Paper | ScholarLens