2013•Liver TransplantationOpen access

Hemodynamic changes in the hepatic circulation after the modulation of the splenic circulation in an in vivo human experimental model

Nobuhisa Akamatsu, Yasuhiko Sugawara, Shouichi Satou, T Mitsui, Riki Ninomiya, Masahiko Komagome, Fumiaki Ozawa, Yoshifumi Beck

Open full text 26 citations

Abstract

Recent advances in liver surgery have highlighted the effects of the splenic circulation on the hepatic circulation with respect to the hepatic arterial buffer response (HABR). The aim of the present study was to investigate the actual hemodynamic effects of splenic artery embolization/ligation and splenectomy on the hepatic circulation in patients who underwent pancreaticoduodenectomy through in vivo experimental models. In vivo models of splenic artery embolization/ligation (only splenic artery clamping) and splenectomy (simultaneous clamping of both the splenic artery and the splenic vein) were created in 40 patients who underwent pancreaticoduodenectomy for various reasons. The portal venous flow velocity, the portal venous flow volume, the hepatic arterial flow velocity, and the hepatic arterial resistance index were measured with color Doppler ultrasonography. Clamping of the splenic artery induced an immediate and significant increase (16%) in the hepatic artery velocity (P < 0.001), and the portal venous flow also decreased significantly (10%, P = 0.03). Fifteen minutes after the clamping of the splenic artery, the hepatic artery velocity remained significantly increased at the level of the initial clamping, and the portal venous flow significantly decreased (16%, P < 0.001). Clamping of the splenic vein, which was performed after the clamping of the splenic artery, resulted in an immediate and significant decrease (30%) in the portal venous flow (P < 0.001), but the hepatic arterial flow was not affected. Fifteen minutes after the clamping of the splenic vein, there was no change in the portal flow, which remained significantly lower (28%) than the flow in controls, whereas the hepatic arterial flow further significantly increased (31%, P < 0.001). In conclusion, our findings indicate that both splenic artery embolization/ligation and splenectomy are effective for increasing hepatic arterial flow and decreasing portal flow, with splenectomy providing a greater advantage. The HABR underlies these hemodynamic changes.

Open-access reader

About this research paper

What this paper is about

Recent advances in liver surgery have highlighted the effects of the splenic circulation on the hepatic circulation with respect to the hepatic arterial buffer response (HABR). The aim of the present study was to investigate the actual hemodynamic effects of splenic artery embolization/ligation and splenectomy on the hepatic circulation in patients who underwent pancreaticoduodenectomy through in vivo experimental models. In vivo models of splenic artery embolization/ligation (only splenic artery clamping) and splenectomy (simultaneous clamping of both the splenic artery and the splenic vein) were created in 40 patients who underwent pancreaticoduodenectomy for various reasons. The portal venous flow velocity, the portal venous flow volume, the hepatic arterial flow velocity, and the hepatic arterial resistance index were measured with color Doppler ultrasonography. Clamping of the splenic artery induced an immediate and significant increase (16%) in the hepatic artery velocity (P < 0.001), and the portal venous flow also decreased significantly (10%, P = 0.03). Fifteen minutes after the clamping of the splenic artery, the hepatic artery velocity remained significantly increased at the level of the initial clamping, and the portal venous flow significantly decreased (16%, P < 0.001). Clamping of the splenic vein, which was performed after the clamping of the splenic artery, resulted in an immediate and significant decrease (30%) in the portal venous flow (P < 0.001), but the hepatic arterial flow was not affected. Fifteen minutes after the clamping of the splenic vein, there was no change in the portal flow, which remained significantly lower (28%) than the flow in controls, whereas the hepatic arterial flow further significantly increased (31%, P < 0.001). In conclusion, our findings indicate that both splenic artery embolization/ligation and splenectomy are effective for increasing hepatic arterial flow and decreasing portal flow, with splenectomy providing a greater advantage. The HABR underlies these hemodynamic changes.

Why it matters

OpenAlex reports 26 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Recent advances in liver surgery have highlighted the effects of the splenic circulation on the hepatic circulation with respect to the hepatic arterial buffer response (HABR). The aim of the present study was to investigate the actual hemodynamic effects of splenic artery embolization/ligation and splenectomy on the hepatic circulation in patients who underwent pancreaticoduodenectomy through in vivo experimental models. In vivo models of splenic artery embolization/ligation (only splenic artery clamping) and splenectomy (simultaneous clamping of both the splenic artery and the splenic vein) were created in 40 patients who underwent pancreaticoduodenectomy for various reasons. The portal venous flow velocity, the portal venous flow volume, the hepatic arterial flow velocity, and the hepatic arterial resistance index were measured with color Doppler ultrasonography. Clamping of the splenic artery induced an immediate and significant increase (16%) in the hepatic artery velocity (P < 0.001), and the portal venous flow also decreased significantly (10%, P = 0.03). Fifteen minutes after the clamping of the splenic artery, the hepatic artery velocity remained significantly increased at the level of the initial clamping, and the portal venous flow significantly decreased (16%, P < 0.001). Clamping of the splenic vein, which was performed after the clamping of the splenic artery, resulted in an immediate and significant decrease (30%) in the portal venous flow (P < 0.001), but the hepatic arterial flow was not affected. Fifteen minutes after the clamping of the splenic vein, there was no change in the portal flow, which remained significantly lower (28%) than the flow in controls, whereas the hepatic arterial flow further significantly increased (31%, P < 0.001). In conclusion, our findings indicate that both splenic artery embolization/ligation and splenectomy are effective for increasing hepatic arterial flow and decreasing portal flow, with splenectomy providing a greater advantage. The HABR underlies these hemodynamic changes.

Key concepts: Medicine, Splenic artery, Splenic vein, Hemodynamics, Artery, Portal venous pressure, Blood flow, Splenectomy

Related papers

Back to paper searchBrowse research topicsOriginal source
Hemodynamic changes in the hepatic circulation after the modulation of the splenic circulation in an in vivo human experimental model — Research Paper | ScholarLens