2010IEEE Transactions on Microwave Theory and TechniquesRequires access

New Isolation Circuits of Compact Impedance-Transforming 3-dB Baluns for Theoretically Perfect Isolation and Matching

Hee‐Ran Ahn, T. Itoh

Open publisher page 33 citations

Abstract

New isolation circuits and design equations of compact impedance-transforming 3-dB baluns are suggested for theoretically perfect isolation and perfect matching at all ports. Any balun consists of two impedance transformers, being 180° out of phase, and an isolation circuit. For compactness, the impedance transformers need to be reduced and the isolation circuits should depend on phase delay of the compact impedance transformers. The compact balun with -90° phase delay of the compact impedance transformer is called the compact II-type balun and the one with non -90° phase delay is called the constant voltage-standing-wave-ratio type transmission-line impedance transformer (CVT) balun. Three isolation circuits are derived for the compact II-type baluns and five for the CVT baluns. Using the isolation circuits derived, the two types of compact baluns are fabricated and measured at a design center frequency of 1.5 GHz. The measured results have good agreement with prediction, showing power divisions of -2.9 and -3.3 dB (- 2.8 and -3.25 dB ), phase difference between two output signals of 181.8°(178.5°) , matching performance of -21.8, -31.8, and -33.8 dB ( -24, -22, and - 28 dB), and isolation of better than 40 dB (27 dB) for the compact II-type (CVT) balun.

About this research paper

What this paper is about

New isolation circuits and design equations of compact impedance-transforming 3-dB baluns are suggested for theoretically perfect isolation and perfect matching at all ports. Any balun consists of two impedance transformers, being 180° out of phase, and an isolation circuit. For compactness, the impedance transformers need to be reduced and the isolation circuits should depend on phase delay of the compact impedance transformers. The compact balun with -90° phase delay of the compact impedance transformer is called the compact II-type balun and the one with non -90° phase delay is called the constant voltage-standing-wave-ratio type transmission-line impedance transformer (CVT) balun. Three isolation circuits are derived for the compact II-type baluns and five for the CVT baluns. Using the isolation circuits derived, the two types of compact baluns are fabricated and measured at a design center frequency of 1.5 GHz. The measured results have good agreement with prediction, showing power divisions of -2.9 and -3.3 dB (- 2.8 and -3.25 dB ), phase difference between two output signals of 181.8°(178.5°) , matching performance of -21.8, -31.8, and -33.8 dB ( -24, -22, and - 28 dB), and isolation of better than 40 dB (27 dB) for the compact II-type (CVT) balun.

Why it matters

OpenAlex reports 33 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

New isolation circuits and design equations of compact impedance-transforming 3-dB baluns are suggested for theoretically perfect isolation and perfect matching at all ports. Any balun consists of two impedance transformers, being 180° out of phase, and an isolation circuit. For compactness, the impedance transformers need to be reduced and the isolation circuits should depend on phase delay of the compact impedance transformers. The compact balun with -90° phase delay of the compact impedance transformer is called the compact II-type balun and the one with non -90° phase delay is called the constant voltage-standing-wave-ratio type transmission-line impedance transformer (CVT) balun. Three isolation circuits are derived for the compact II-type baluns and five for the CVT baluns. Using the isolation circuits derived, the two types of compact baluns are fabricated and measured at a design center frequency of 1.5 GHz. The measured results have good agreement with prediction, showing power divisions of -2.9 and -3.3 dB (- 2.8 and -3.25 dB ), phase difference between two output signals of 181.8°(178.5°) , matching performance of -21.8, -31.8, and -33.8 dB ( -24, -22, and - 28 dB), and isolation of better than 40 dB (27 dB) for the compact II-type (CVT) balun.

Key concepts: Balun, Impedance matching, Transformer, Electrical engineering, Electrical impedance, Electronic circuit, Quarter-wave impedance transformer, Electronic engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
New Isolation Circuits of Compact Impedance-Transforming 3-dB Baluns for Theoretically Perfect Isolation and Matching — Research Paper | ScholarLens