2004New England Journal of MedicineRequires access

Cardiac-Resynchronization Therapy with or without an Implantable Defibrillator in Advanced Chronic Heart Failure

Michael R. Bristow, Leslie A. Saxon, John Boehmer, Steven K. Krueger, David A. Kass, Teresa De Marco, Peter E. Carson, Lorenzo A. DiCarlo, David L. DeMets, Bill G. White, Dale W. DeVries, Arthur M. Feldman

Open publisher page 5,841 citations

Abstract

BACKGROUND: We tested the hypothesis that prophylactic cardiac-resynchronization therapy in the form of biventricular stimulation with a pacemaker with or without a defibrillator would reduce the risk of death and hospitalization among patients with advanced chronic heart failure and intraventricular conduction delays. METHODS: A total of 1520 patients who had advanced heart failure (New York Heart Association class III or IV) due to ischemic or nonischemic cardiomyopathies and a QRS interval of at least 120 msec were randomly assigned in a 1:2:2 ratio to receive optimal pharmacologic therapy (diuretics, angiotensin-converting-enzyme inhibitors, beta-blockers, and spironolactone) alone or in combination with cardiac-resynchronization therapy with either a pacemaker or a pacemaker-defibrillator. The primary composite end point was the time to death from or hospitalization for any cause. RESULTS: As compared with optimal pharmacologic therapy alone, cardiac-resynchronization therapy with a pacemaker decreased the risk of the primary end point (hazard ratio, 0.81; P=0.014), as did cardiac-resynchronization therapy with a pacemaker-defibrillator (hazard ratio, 0.80; P=0.01). The risk of the combined end point of death from or hospitalization for heart failure was reduced by 34 percent in the pacemaker group (P<0.002) and by 40 percent in the pacemaker-defibrillator group (P<0.001 for the comparison with the pharmacologic-therapy group). A pacemaker reduced the risk of the secondary end point of death from any cause by 24 percent (P=0.059), and a pacemaker-defibrillator reduced the risk by 36 percent (P=0.003). CONCLUSIONS: In patients with advanced heart failure and a prolonged QRS interval, cardiac-resynchronization therapy decreases the combined risk of death from any cause or first hospitalization and, when combined with an implantable defibrillator, significantly reduces mortality.

About this research paper

What this paper is about

BACKGROUND: We tested the hypothesis that prophylactic cardiac-resynchronization therapy in the form of biventricular stimulation with a pacemaker with or without a defibrillator would reduce the risk of death and hospitalization among patients with advanced chronic heart failure and intraventricular conduction delays. METHODS: A total of 1520 patients who had advanced heart failure (New York Heart Association class III or IV) due to ischemic or nonischemic cardiomyopathies and a QRS interval of at least 120 msec were randomly assigned in a 1:2:2 ratio to receive optimal pharmacologic therapy (diuretics, angiotensin-converting-enzyme inhibitors, beta-blockers, and spironolactone) alone or in combination with cardiac-resynchronization therapy with either a pacemaker or a pacemaker-defibrillator. The primary composite end point was the time to death from or hospitalization for any cause. RESULTS: As compared with optimal pharmacologic therapy alone, cardiac-resynchronization therapy with a pacemaker decreased the risk of the primary end point (hazard ratio, 0.81; P=0.014), as did cardiac-resynchronization therapy with a pacemaker-defibrillator (hazard ratio, 0.80; P=0.01). The risk of the combined end point of death from or hospitalization for heart failure was reduced by 34 percent in the pacemaker group (P<0.002) and by 40 percent in the pacemaker-defibrillator group (P<0.001 for the comparison with the pharmacologic-therapy group). A pacemaker reduced the risk of the secondary end point of death from any cause by 24 percent (P=0.059), and a pacemaker-defibrillator reduced the risk by 36 percent (P=0.003). CONCLUSIONS: In patients with advanced heart failure and a prolonged QRS interval, cardiac-resynchronization therapy decreases the combined risk of death from any cause or first hospitalization and, when combined with an implantable defibrillator, significantly reduces mortality.

Why it matters

OpenAlex reports 5841 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: We tested the hypothesis that prophylactic cardiac-resynchronization therapy in the form of biventricular stimulation with a pacemaker with or without a defibrillator would reduce the risk of death and hospitalization among patients with advanced chronic heart failure and intraventricular conduction delays. METHODS: A total of 1520 patients who had advanced heart failure (New York Heart Association class III or IV) due to ischemic or nonischemic cardiomyopathies and a QRS interval of at least 120 msec were randomly assigned in a 1:2:2 ratio to receive optimal pharmacologic therapy (diuretics, angiotensin-converting-enzyme inhibitors, beta-blockers, and spironolactone) alone or in combination with cardiac-resynchronization therapy with either a pacemaker or a pacemaker-defibrillator. The primary composite end point was the time to death from or hospitalization for any cause. RESULTS: As compared with optimal pharmacologic therapy alone, cardiac-resynchronization therapy with a pacemaker decreased the risk of the primary end point (hazard ratio, 0.81; P=0.014), as did cardiac-resynchronization therapy with a pacemaker-defibrillator (hazard ratio, 0.80; P=0.01). The risk of the combined end point of death from or hospitalization for heart failure was reduced by 34 percent in the pacemaker group (P<0.002) and by 40 percent in the pacemaker-defibrillator group (P<0.001 for the comparison with the pharmacologic-therapy group). A pacemaker reduced the risk of the secondary end point of death from any cause by 24 percent (P=0.059), and a pacemaker-defibrillator reduced the risk by 36 percent (P=0.003). CONCLUSIONS: In patients with advanced heart failure and a prolonged QRS interval, cardiac-resynchronization therapy decreases the combined risk of death from any cause or first hospitalization and, when combined with an implantable defibrillator, significantly reduces mortality.

Key concepts: Medicine, Cardiac resynchronization therapy, Heart failure, Cardiology, Internal medicine, Implantable cardioverter-defibrillator, Ejection fraction

Related papers

Back to paper searchBrowse research topicsOriginal source
Cardiac-Resynchronization Therapy with or without an Implantable Defibrillator in Advanced Chronic Heart Failure — Research Paper | ScholarLens