Study on evaluation of building energy efficiency rate using BIM based simulation tool
Sang-tae No
Abstract
Sang-tae No
Abstract
Energy saving of buildings is a big issue because building energy occupies about 25% of national energy. To reduce building energy, many countries try to control building energy by laws, such as building energy regulations. This study has two objectives. The first is to evaluate building energy efficiency rate of a specific building using annual energy analysis software based on BIM tools. The second objective is to reduce building energy usage adopting passive and active architectural strategies under the Korean building energy rating regulation. A newly constructed public library building was selected as energy simulation base model, and a few active and passive energy saving strategies were applied to the same building. Energy plus was adopted as a simulation tool. The calculated annual source energy usage per area for alt model was 210.7 kWh/m2 yr, and the value for base model was 355 kWh/m2 yr. The building energy efficiency rate for alt model is the first class under Korean building energy rating regulation.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Energy saving of buildings is a big issue because building energy occupies about 25% of national energy. To reduce building energy, many countries try to control building energy by laws, such as building energy regulations. This study has two objectives. The first is to evaluate building energy efficiency rate of a specific building using annual energy analysis software based on BIM tools. The second objective is to reduce building energy usage adopting passive and active architectural strategies under the Korean building energy rating regulation. A newly constructed public library building was selected as energy simulation base model, and a few active and passive energy saving strategies were applied to the same building. Energy plus was adopted as a simulation tool. The calculated annual source energy usage per area for alt model was 210.7 kWh/m2 yr, and the value for base model was 355 kWh/m2 yr. The building energy efficiency rate for alt model is the first class under Korean building energy rating regulation.
Key concepts: Energy (signal processing), Efficient energy use, Architectural engineering, Building model, Building information modeling, Building science, Engineering, Building energy simulation