2004Clinical Cancer ResearchRequires access

Is a Lymph Node Detected by the Dye-Guided Method a True Sentinel Node in Gastric Cancer?

Hirohisa Osaka, Masakazu Yashiro, Tetsuji Sawada, Kei Katsuragi, Kosei Hirakawa

Open publisher page 52 citations

Abstract

PURPOSE: A sentinel node is defined as the initial lymph node, to which cancer cells metastasize from a primary tumor. Recently, sentinel node navigation surgery has been done using the dye-guided method. However, no study has shown that a lymph node detected by the dye-guided method is the true sentinel node from the viewpoint of micrometastasis. Micrometastases of lymph nodes, in which no metastasis was found by H&E staining, were examined to establish whether a lymph node detected by the dye-guided method is the true sentinel node. EXPERIMENTAL DESIGN: Isosulfan blue was injected endoscopically as the dye-guided method at a submucosal lesion of early gastric cancer. Total 345 lymph nodes, including 150 blue-dyed lymph nodes and 195 nondyed lymph nodes were collected from 57 patients and each was quartered. Two quarters were examined histologically by H&E staining and cytokeratin staining. The other specimens were used for quantitative reverse transcription-PCR of CEA and CK20 mRNAs. RESULTS: Lymph node disease was not found in any of 345 lymph nodes from the 57 patients by routine H&E staining. By contrast, either CEA or CK20 mRNA expression was detected in 21 of 345 lymph nodes obtained from the 10 (18%) of 57 patients by quantitative reverse transcription-PCR. Eight of the 21 micrometastasis-positive lymph nodes were confirmed to be positive for cytokeratin staining. Although micrometastasis of nondyed lymph nodes was found in three cases, these were included in the 10 cases with micrometastasis of blue-dyed nodes, such that there was no patient who only had micrometastasis in nondyed nodes. Six of 10 cases were micrometastasis-positive in a single node; all six were blue-dyed nodes. CONCLUSION: A lymph node detected by the dye-guided method should be a true sentinel node to which cancer cells metastasize initially.

About this research paper

What this paper is about

PURPOSE: A sentinel node is defined as the initial lymph node, to which cancer cells metastasize from a primary tumor. Recently, sentinel node navigation surgery has been done using the dye-guided method. However, no study has shown that a lymph node detected by the dye-guided method is the true sentinel node from the viewpoint of micrometastasis. Micrometastases of lymph nodes, in which no metastasis was found by H&E staining, were examined to establish whether a lymph node detected by the dye-guided method is the true sentinel node. EXPERIMENTAL DESIGN: Isosulfan blue was injected endoscopically as the dye-guided method at a submucosal lesion of early gastric cancer. Total 345 lymph nodes, including 150 blue-dyed lymph nodes and 195 nondyed lymph nodes were collected from 57 patients and each was quartered. Two quarters were examined histologically by H&E staining and cytokeratin staining. The other specimens were used for quantitative reverse transcription-PCR of CEA and CK20 mRNAs. RESULTS: Lymph node disease was not found in any of 345 lymph nodes from the 57 patients by routine H&E staining. By contrast, either CEA or CK20 mRNA expression was detected in 21 of 345 lymph nodes obtained from the 10 (18%) of 57 patients by quantitative reverse transcription-PCR. Eight of the 21 micrometastasis-positive lymph nodes were confirmed to be positive for cytokeratin staining. Although micrometastasis of nondyed lymph nodes was found in three cases, these were included in the 10 cases with micrometastasis of blue-dyed nodes, such that there was no patient who only had micrometastasis in nondyed nodes. Six of 10 cases were micrometastasis-positive in a single node; all six were blue-dyed nodes. CONCLUSION: A lymph node detected by the dye-guided method should be a true sentinel node to which cancer cells metastasize initially.

Why it matters

OpenAlex reports 52 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: A sentinel node is defined as the initial lymph node, to which cancer cells metastasize from a primary tumor. Recently, sentinel node navigation surgery has been done using the dye-guided method. However, no study has shown that a lymph node detected by the dye-guided method is the true sentinel node from the viewpoint of micrometastasis. Micrometastases of lymph nodes, in which no metastasis was found by H&E staining, were examined to establish whether a lymph node detected by the dye-guided method is the true sentinel node. EXPERIMENTAL DESIGN: Isosulfan blue was injected endoscopically as the dye-guided method at a submucosal lesion of early gastric cancer. Total 345 lymph nodes, including 150 blue-dyed lymph nodes and 195 nondyed lymph nodes were collected from 57 patients and each was quartered. Two quarters were examined histologically by H&E staining and cytokeratin staining. The other specimens were used for quantitative reverse transcription-PCR of CEA and CK20 mRNAs. RESULTS: Lymph node disease was not found in any of 345 lymph nodes from the 57 patients by routine H&E staining. By contrast, either CEA or CK20 mRNA expression was detected in 21 of 345 lymph nodes obtained from the 10 (18%) of 57 patients by quantitative reverse transcription-PCR. Eight of the 21 micrometastasis-positive lymph nodes were confirmed to be positive for cytokeratin staining. Although micrometastasis of nondyed lymph nodes was found in three cases, these were included in the 10 cases with micrometastasis of blue-dyed nodes, such that there was no patient who only had micrometastasis in nondyed nodes. Six of 10 cases were micrometastasis-positive in a single node; all six were blue-dyed nodes. CONCLUSION: A lymph node detected by the dye-guided method should be a true sentinel node to which cancer cells metastasize initially.

Key concepts: Micrometastasis, Lymph, Medicine, Lymph node, Cytokeratin, Sentinel lymph node, Pathology, Staining

Related papers

Back to paper searchBrowse research topicsOriginal source
Is a Lymph Node Detected by the Dye-Guided Method a True Sentinel Node in Gastric Cancer? — Research Paper | ScholarLens