1998•Journal of Geotechnical and Geoenvironmental EngineeringRequires access

Slope Stability of Geosynthetic Clay Liner Test Plots

David E. Daniel, Robert M. Koerner, Rudolph Bonaparte, Robert E. Landreth, David A. Carson, Heather B. Scranton

Open publisher page 71 citations

Abstract

Fourteen full-scale field test plots containing five types of geosynthetic clay liners (GCLs) were constructed on 2H:1V and 3H:1V slopes for the purpose of assessing slope stability. The test plots were designed to simulate typical final cover systems for landfills. Slides occurred in two of the 2H:1V test plots along interfaces between textured geomembranes and the woven geotextile components of internally reinforced GCLs. One additional slide occurred within the unreinforced GCL component of a 2H:1V test plot, when the GCL unexpectedly became hydrated. All 3H:1V slopes have remained stable. Results of laboratory direct shear tests compared favorably with field observations, providing support for the current design procedures that engineers are using for assessing the stability of slopes containing GCLs.

About this research paper

What this paper is about

Fourteen full-scale field test plots containing five types of geosynthetic clay liners (GCLs) were constructed on 2H:1V and 3H:1V slopes for the purpose of assessing slope stability. The test plots were designed to simulate typical final cover systems for landfills. Slides occurred in two of the 2H:1V test plots along interfaces between textured geomembranes and the woven geotextile components of internally reinforced GCLs. One additional slide occurred within the unreinforced GCL component of a 2H:1V test plot, when the GCL unexpectedly became hydrated. All 3H:1V slopes have remained stable. Results of laboratory direct shear tests compared favorably with field observations, providing support for the current design procedures that engineers are using for assessing the stability of slopes containing GCLs.

Why it matters

OpenAlex reports 71 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Fourteen full-scale field test plots containing five types of geosynthetic clay liners (GCLs) were constructed on 2H:1V and 3H:1V slopes for the purpose of assessing slope stability. The test plots were designed to simulate typical final cover systems for landfills. Slides occurred in two of the 2H:1V test plots along interfaces between textured geomembranes and the woven geotextile components of internally reinforced GCLs. One additional slide occurred within the unreinforced GCL component of a 2H:1V test plot, when the GCL unexpectedly became hydrated. All 3H:1V slopes have remained stable. Results of laboratory direct shear tests compared favorably with field observations, providing support for the current design procedures that engineers are using for assessing the stability of slopes containing GCLs.

Key concepts: Geotextile, Geomembrane, Geotechnical engineering, Geosynthetic clay liner, Geosynthetics, Direct shear test, Slope stability, Geology

Related papers

Back to paper searchBrowse research topicsOriginal source
Slope Stability of Geosynthetic Clay Liner Test Plots — Research Paper | ScholarLens