2010Yonsei Medical JournalOpen access

Impact of Prostate Volume on the Efficacy of High-Power Potassium-Titanyl-Phosphate Photoselective Vaporization of the Prostate: A Retrospective, Short-Term Follow-Up Study on Evaluating Feasibility and Safety

Ja Hyeon Ku, Soo Woong Kim, Jae‐Seung Paick

Open full text 4 citations

Abstract

PURPOSE: We determined the impact of prostate volume on the efficacy of the high-power (80 W) potassium-titanyl-phosphate (KTP) photoselective laser vaporization of the prostate in men with lower urinary tract symptoms (LUTS). MATERIALS AND METHODS: Patients were stratified into 3 groups according to prostate volume: '< 40 g' (n = 49) and '40-59 g' (n = 49) and '≥ 60 g' (n = 22). Median follow-up was 9 months (range 6 to 21). RESULTS: No differences in age and follow-up duration were observed in the three groups. At baseline, no significant differences were noted in the three groups in terms of the International Prostate Symptom Score (IPSS) (21.4, 19.4 and 19.1; p = 0.412) as well as the maximum flow rate (Qmax) (10.2, 9.2, and 8.6 mL/s; p = 0.291) and post-void residual (PVR) (66.2, 80.4, and 71.5 mL; p = 0.856). The mean operative times were 30.9, 46.9, and 58.6 minutes (p< 0.001) and total median energy deliveries for each group were 62.3, 97.6, and 135.9 kJ, respectively (p< 0.001). No severe intraoperative complication was observed. At the last follow-up, these parameters improved significantly regardless of prostate volume, and the IPSS (11.1, 9.4, and 12.3; p = 0.286) as well as Qmax (15.9, 15.9, and 14.2 mL/s; p = 0.690) and PVR (33.7, 28.4, and 14.2 mL; p = 0.395) were not significantly different among the groups. CONCLUSION: Although a larger prostate requires more time and energy delivery, photoselective laser vaporization of the prostate is safe and efficacious for patients with LUTS regardless of prostate volume.

Open-access reader

About this research paper

What this paper is about

PURPOSE: We determined the impact of prostate volume on the efficacy of the high-power (80 W) potassium-titanyl-phosphate (KTP) photoselective laser vaporization of the prostate in men with lower urinary tract symptoms (LUTS). MATERIALS AND METHODS: Patients were stratified into 3 groups according to prostate volume: '< 40 g' (n = 49) and '40-59 g' (n = 49) and '≥ 60 g' (n = 22). Median follow-up was 9 months (range 6 to 21). RESULTS: No differences in age and follow-up duration were observed in the three groups. At baseline, no significant differences were noted in the three groups in terms of the International Prostate Symptom Score (IPSS) (21.4, 19.4 and 19.1; p = 0.412) as well as the maximum flow rate (Qmax) (10.2, 9.2, and 8.6 mL/s; p = 0.291) and post-void residual (PVR) (66.2, 80.4, and 71.5 mL; p = 0.856). The mean operative times were 30.9, 46.9, and 58.6 minutes (p< 0.001) and total median energy deliveries for each group were 62.3, 97.6, and 135.9 kJ, respectively (p< 0.001). No severe intraoperative complication was observed. At the last follow-up, these parameters improved significantly regardless of prostate volume, and the IPSS (11.1, 9.4, and 12.3; p = 0.286) as well as Qmax (15.9, 15.9, and 14.2 mL/s; p = 0.690) and PVR (33.7, 28.4, and 14.2 mL; p = 0.395) were not significantly different among the groups. CONCLUSION: Although a larger prostate requires more time and energy delivery, photoselective laser vaporization of the prostate is safe and efficacious for patients with LUTS regardless of prostate volume.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: We determined the impact of prostate volume on the efficacy of the high-power (80 W) potassium-titanyl-phosphate (KTP) photoselective laser vaporization of the prostate in men with lower urinary tract symptoms (LUTS). MATERIALS AND METHODS: Patients were stratified into 3 groups according to prostate volume: '< 40 g' (n = 49) and '40-59 g' (n = 49) and '≥ 60 g' (n = 22). Median follow-up was 9 months (range 6 to 21). RESULTS: No differences in age and follow-up duration were observed in the three groups. At baseline, no significant differences were noted in the three groups in terms of the International Prostate Symptom Score (IPSS) (21.4, 19.4 and 19.1; p = 0.412) as well as the maximum flow rate (Qmax) (10.2, 9.2, and 8.6 mL/s; p = 0.291) and post-void residual (PVR) (66.2, 80.4, and 71.5 mL; p = 0.856). The mean operative times were 30.9, 46.9, and 58.6 minutes (p< 0.001) and total median energy deliveries for each group were 62.3, 97.6, and 135.9 kJ, respectively (p< 0.001). No severe intraoperative complication was observed. At the last follow-up, these parameters improved significantly regardless of prostate volume, and the IPSS (11.1, 9.4, and 12.3; p = 0.286) as well as Qmax (15.9, 15.9, and 14.2 mL/s; p = 0.690) and PVR (33.7, 28.4, and 14.2 mL; p = 0.395) were not significantly different among the groups. CONCLUSION: Although a larger prostate requires more time and energy delivery, photoselective laser vaporization of the prostate is safe and efficacious for patients with LUTS regardless of prostate volume.

Key concepts: Potassium titanyl phosphate, Medicine, Prostate, Urology, International Prostate Symptom Score, Lower urinary tract symptoms, Surgery, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Impact of Prostate Volume on the Efficacy of High-Power Potassium-Titanyl-Phosphate Photoselective Vaporization of the Prostate: A Retrospective, Short-Term Follow-Up Study on Evaluating Feasibility and Safety — Research Paper | ScholarLens