2003Prenatal DiagnosisRequires access

Ductus venosus assessment at the time of nuchal translucency measurement in the detection of fetal aneuploidy

ANTONI BORRELL, Josep Maria Martínez, Agustí Serés, Virginia Borobio, Vicenç Cararach, Albert Fortuny

Open publisher page 82 citations

Abstract

OBJECTIVE: To assess the potential value of ductus venosus Doppler studies in the detection of fetal aneuploidy on measurement of nuchal translucency. METHODS: The pulsatility index for veins (PIV) and the lowest velocity during atrial contraction (A-wave) were determined in the fetal ductus venosus in 3382 consecutive pregnancies at 10 to 14 weeks and studied from December 1996 to December 2001. Nuchal translucency was also measured. The population studied included 1664 pregnancies at high risk and 1718 at low risk for fetal aneuploidy. RESULTS: In relation to the prenatal detection of trisomy 21, the ductus venosus PIV was increased in 75% (36/48), the A-wave was decreased in 58% (28/48), and nuchal translucency was enlarged in 81% (39/48) of the trisomy 21 fetuses [71% (22/31) when nuchal translucency referrals were excluded]. The corresponding figures for trisomies 18 and 13 were 71, 58 and 83%, respectively, being 33, 33 and 33% for other unbalanced anomalies. CONCLUSION: There is a high proportion of fetuses with trisomies 21, 18 and 13 (around 75%) in which the ductus venosus PIV is increased (above the 95th percentile) at 10 to 14 weeks, this proportion being similar to that observed for increased nuchal translucency measurement.

About this research paper

What this paper is about

OBJECTIVE: To assess the potential value of ductus venosus Doppler studies in the detection of fetal aneuploidy on measurement of nuchal translucency. METHODS: The pulsatility index for veins (PIV) and the lowest velocity during atrial contraction (A-wave) were determined in the fetal ductus venosus in 3382 consecutive pregnancies at 10 to 14 weeks and studied from December 1996 to December 2001. Nuchal translucency was also measured. The population studied included 1664 pregnancies at high risk and 1718 at low risk for fetal aneuploidy. RESULTS: In relation to the prenatal detection of trisomy 21, the ductus venosus PIV was increased in 75% (36/48), the A-wave was decreased in 58% (28/48), and nuchal translucency was enlarged in 81% (39/48) of the trisomy 21 fetuses [71% (22/31) when nuchal translucency referrals were excluded]. The corresponding figures for trisomies 18 and 13 were 71, 58 and 83%, respectively, being 33, 33 and 33% for other unbalanced anomalies. CONCLUSION: There is a high proportion of fetuses with trisomies 21, 18 and 13 (around 75%) in which the ductus venosus PIV is increased (above the 95th percentile) at 10 to 14 weeks, this proportion being similar to that observed for increased nuchal translucency measurement.

Why it matters

OpenAlex reports 82 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To assess the potential value of ductus venosus Doppler studies in the detection of fetal aneuploidy on measurement of nuchal translucency. METHODS: The pulsatility index for veins (PIV) and the lowest velocity during atrial contraction (A-wave) were determined in the fetal ductus venosus in 3382 consecutive pregnancies at 10 to 14 weeks and studied from December 1996 to December 2001. Nuchal translucency was also measured. The population studied included 1664 pregnancies at high risk and 1718 at low risk for fetal aneuploidy. RESULTS: In relation to the prenatal detection of trisomy 21, the ductus venosus PIV was increased in 75% (36/48), the A-wave was decreased in 58% (28/48), and nuchal translucency was enlarged in 81% (39/48) of the trisomy 21 fetuses [71% (22/31) when nuchal translucency referrals were excluded]. The corresponding figures for trisomies 18 and 13 were 71, 58 and 83%, respectively, being 33, 33 and 33% for other unbalanced anomalies. CONCLUSION: There is a high proportion of fetuses with trisomies 21, 18 and 13 (around 75%) in which the ductus venosus PIV is increased (above the 95th percentile) at 10 to 14 weeks, this proportion being similar to that observed for increased nuchal translucency measurement.

Key concepts: Ductus venosus, Nuchal Translucency Measurement, Medicine, Aneuploidy, Trisomy, Fetus, Population, Nuchal translucency

Related papers

Back to paper searchBrowse research topicsOriginal source
Ductus venosus assessment at the time of nuchal translucency measurement in the detection of fetal aneuploidy — Research Paper | ScholarLens