2007•Journal of Applied Oral ScienceOpen access

Shear bond strength of metallic brackets photo-activated with light-emitting diode (LED) at different exposure times

Emanuel Braga Rêgo, Fábio Lourenço Romano

Open full text 11 citations

Abstract

The purpose of this study was to compare the shear bond strength of orthodontic metallic brackets photo-activated with two different light-curing sources at different exposure times: halogen light (XL 1500, 3M ESPE) and LED light (Ortholux, 3M Unitek). Sixty bovine permanent lower incisors were inserted into PVC tubes containing plaster. The buccal surfaces were cleaned with pumice and water, and then etched with 37% phosphoric acid gel. The XT Primer bonding agent (3M Unitek) was applied to the enamel surfaces and the metallic pre-coated brackets (Transbond APC II system, 3M Unitek) were attached to upper central incisors. The teeth were randomly divided into four groups (n=15). In Group I (Control), halogen light was used for 40 seconds, while in Groups II, III, and IV were light-cured with LED light unit for 40, 10, and 5 seconds, respectively. The teeth were stored in distilled water at 37 degrees C for 24 hours. The brackets were submitted to shear bond strength test in universal testing machine (Instron) at a crosshead speed of 0.5 mm/minute. Shear bond strength means (MPa) were 4.87 for Group I; 5.89 for Group II; 4.83 for Group III, and 4.39 for Group IV. Tukey's test detected no statistically significant differences among the groups regarding the shear bond strength (p>0.05). Neither of the types of light-curing sources or exposure times influenced the shear bond strength of metallic brackets.

Open-access reader

About this research paper

What this paper is about

The purpose of this study was to compare the shear bond strength of orthodontic metallic brackets photo-activated with two different light-curing sources at different exposure times: halogen light (XL 1500, 3M ESPE) and LED light (Ortholux, 3M Unitek). Sixty bovine permanent lower incisors were inserted into PVC tubes containing plaster. The buccal surfaces were cleaned with pumice and water, and then etched with 37% phosphoric acid gel. The XT Primer bonding agent (3M Unitek) was applied to the enamel surfaces and the metallic pre-coated brackets (Transbond APC II system, 3M Unitek) were attached to upper central incisors. The teeth were randomly divided into four groups (n=15). In Group I (Control), halogen light was used for 40 seconds, while in Groups II, III, and IV were light-cured with LED light unit for 40, 10, and 5 seconds, respectively. The teeth were stored in distilled water at 37 degrees C for 24 hours. The brackets were submitted to shear bond strength test in universal testing machine (Instron) at a crosshead speed of 0.5 mm/minute. Shear bond strength means (MPa) were 4.87 for Group I; 5.89 for Group II; 4.83 for Group III, and 4.39 for Group IV. Tukey's test detected no statistically significant differences among the groups regarding the shear bond strength (p>0.05). Neither of the types of light-curing sources or exposure times influenced the shear bond strength of metallic brackets.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The purpose of this study was to compare the shear bond strength of orthodontic metallic brackets photo-activated with two different light-curing sources at different exposure times: halogen light (XL 1500, 3M ESPE) and LED light (Ortholux, 3M Unitek). Sixty bovine permanent lower incisors were inserted into PVC tubes containing plaster. The buccal surfaces were cleaned with pumice and water, and then etched with 37% phosphoric acid gel. The XT Primer bonding agent (3M Unitek) was applied to the enamel surfaces and the metallic pre-coated brackets (Transbond APC II system, 3M Unitek) were attached to upper central incisors. The teeth were randomly divided into four groups (n=15). In Group I (Control), halogen light was used for 40 seconds, while in Groups II, III, and IV were light-cured with LED light unit for 40, 10, and 5 seconds, respectively. The teeth were stored in distilled water at 37 degrees C for 24 hours. The brackets were submitted to shear bond strength test in universal testing machine (Instron) at a crosshead speed of 0.5 mm/minute. Shear bond strength means (MPa) were 4.87 for Group I; 5.89 for Group II; 4.83 for Group III, and 4.39 for Group IV. Tukey's test detected no statistically significant differences among the groups regarding the shear bond strength (p>0.05). Neither of the types of light-curing sources or exposure times influenced the shear bond strength of metallic brackets.

Key concepts: Materials science, Metal, Shear (geology), Diode, Composite material, Light-emitting diode, Optoelectronics, Structural engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Shear bond strength of metallic brackets photo-activated with light-emitting diode (LED) at different exposure times — Research Paper | ScholarLens